Page 15
©
Baxi Heating U.K. Limited 2008.
Figure 5. Appliance dimensions and clearances (Fascia may differ from that shown)
INSTALLER GUIDE
Key
Description
Model
Fascination
Landscape
& Serenity
Visia
Tranquility &
Aspect Glass
A
Appliance height (mm)
599
607
640
612
B
Appliance width (mm)
520
976
930
505
C
Appliance depth into room
(mm)
61
72
40
50
D
Minimum
mandatory
clearance to
combustible
surfaces projecting beyond
the front of appliance
(mm).
10
10
10
10
E
Recommended
clearance
to
non-combustible
surfaces for access
purposes (mm).
10
10
10
10