![Valor Fires 942 Installer And Owner Manual Download Page 35](http://html1.mh-extra.com/html/valor-fires/942/942_installer-and-owner-manual_3291133035.webp)
14. FRONT / CASTINGS INSTALLATION
‘
Dream’ model only.
1.
Place the firefront casting centrally on the hearth in front of the fascia.
2.
Place the bottom front cover casting in position below the fire front casting.
‘
Opulent’ model only.
1.
Place the bottom front cover casting in position below the fire front casting.
‘
Heritage’ model only.
1.
There are two screws located on the upper rear
face of the firefront casting. Locate the two screw
heads through the keyhole slots at the inner sides of
the fascia. If the screw heads do not project enough
or project too far, the screws can be adjusted.
Lower the firefront casting so that it rests on the
hearth (See figure 35).
2.
Hook the front cover casting onto the bottom of
the firefront casting.
15. FULL OPERATING CHECKS
15.1 Check the Control Settings
The control position markings on the fascia are
shown in figure 36.
Please note:
When first turned on from cold, the flames
will appear predominantly blue.
When operating the fire for the first time,
some vapours may be given off which could
set off smoke alarms in the vicinity. These
vapours are quite normal with new appliances.
They are totally harmless and will disappear
after a few hours use
.
1.
Make sure the slider button is at the off
position (At topmost position marked “
O
” on the
fascia).
2.
Open the isolating valve on the inlet ‘T’
connector. Replace the sealing screw and test
around the sealing screw for gas soundness
with a suitable leak detection fluid.
3.
Slide the button to the bottom (ignition)
Page 35
©
Baxi Heating U.K. Limited 2009.
INSTALLER GUIDE
Figure 35. Firefront casting
location
Figure 36. Control settings
(Shown with ‘Dream’ fascia).