6. IGNITION CHECK
Before attempting to install, it is worth checking that the electronic ignition system
performs satisfactorily.
Fit the battery to the ignition block located below the burner tray at the left side (See
figure 9). The positive (+ve) and negative (-ve) terminals are clearly marked on the
body of the igniter unit.
Heritage and Opulent models.
Depress the control pivot plate as far as it
will go. This should close the ignition circuit.
Sparks should be seen tracking from the
electrode pin to the pilot tip (See figure 10).
Dream model.
Attach the slider knob assembly to the
slider using two M4 x 7mm screws supplied
(See figure 11).
Press down the control knob as far as it
will go. This should close the ignition circuit.
Sparks should be seen tracking from the
electrode pin to the
pilot tip (See figure
10).
If there are no sparks make the following checks.
Check condition of battery and that it is
correctly fitted.
If the above is satisfactory, check the ignition
circuit and components - see the servicing and
parts replacement section in this manual.