4. APPLIANCE DATA AND EFFICIENCY
4.1 Appliance data.
Under no circumstances is this fire to be converted to LPG. An LPG conversion kit
does
not
exist for this gas fire.
The appliance information label is on the inner face of the back panel at the lower left
hand side. It is visible when the fascia is removed.
4.2 Efficiency.
The efficiency of this appliance has been measured as specified in BS 7977 - 1 and
the result is as below :
Model
Efficiency % (Gross)
339
71
The gross calorific value of the fuel has been used for this efficiency calculation. The
test data from which it has been calculated has been certified by Advantica
Certification services (0087). The efficiency value may be used in the UK
Government's Standard Assessment Procedure (SAP) for energy rating of dwellings.
Page 8
INSTALLER GUIDE
©
Baxi Heating U.K. Limited 2010.
Gas
Natural (G20)
Inlet Pressure
20mbar
Gross Heat Input
Control Setting 4
5.05kW (17,200Btu/h)
Control Setting 3
3.45kW (11,800Btu/h)
Control Setting 2
1.80kW (6,100Btu/h)
Control Setting 1/IGN
1.55kW (5,300Btu/h)
Burner Test Pressure (Cold)
17.2 + 0.75mbar (6.9 + 0.3in w.g.)
Gas Connection
8mm pipe
Burner Injectors
Upper - Bray Cat. 99 Size 115
Lower - Bray Cat. 99 Size 230A
Pilot & Atmosphere Sensing Device
SIT Ref. OPNG9419
Ignition
Piezo-electric integral with gas tap
Aeration
Non-adjustable