screws each side of the window frame and lifting the unit clear.
9.
Remove the ceramic coal fuel effect pack from the
firebox and keep it safe.
10.
Before attempting to install, it is worth checking
that the piezo electric spark ignition system operates
satisfactorily.
To initiate the spark, temporarily refit the control
knob to the tap spindle. Depress the control knob
and while keeping it depressed, turn anticlockwise
through approximately 60° to the 1/IGN position. A
spark should track from the electrode pin to pilot
burner. If there is no spark or incorrect tracking,
check that the spark gap is between the limits shown
in figure 8. If the spark gap is correct, check the
ignition wiring.
Remove the control knob after checking.
11.
For wall mounted appliances remove the
levelling screws and locknuts from below the feet.
12.
If the fire is fitted to a recessed fireplace, an
extension flue spigot up to a maximum total length of
125mm may be used. The extension must be a tight
fit over the flue spigot and be secured by two self
tapping screws. Note the minimum clearance
required as shown in figure 4.
6.3 Fireplace flue pull.
Close all doors and windows in the room in which
the appliance is to be installed. After confirming with
a match that smoke is drawn into the flue, light a 13
gram smoke pellet and check that there is a definite
flow through the flue. Verify outside that the smoke
exits from one terminal only and that the termination is
suitable. Observe, where possible, upstairs rooms and
loft spaces for signs of escaping smoke indicating a
defective flue. If there is not a definite flow warm the
flue for a few minutes and repeat the smoke pellet test.
If there is still no definite flow the flue may need
remedial work –
Do not fit the appliance until there
is a definite flow through the flue.
Page 18
INSTALLER GUIDE
©
Baxi Heating U.K. Limited 2010.
Figure 8. Pilot spark gap
Figure 7. fascia removal.