MANURE CONTROL
TECHNICAN
’S MANUAL V0.
3
2020-02-19
17
7.2.4
Autowasher
Number of autowasher in the system. The autowasher
icon will appear if there is at least 1 autowasher.
Maximum 5 autowasher.
7.2.5
Unloading
Enable or disable the unloading section. The icon will
appear if the option is enabled. Use with Valmetal Belt
feeder.
7.2.6
Buzzer
PLC output address for the buzzer. Enable or disable
the buzzer if the system as an active alarm.
7.2.7
Unit
Measuring unit for the distribution conveyor. Press to
switch in metric.
7.2.8
Change Node
In that box, you can change the node number for the
smart overload. Enter the
Actual Node
(unprogrammed
overload node generally set at 1) and the
Desired Node
(Master: 2-19, Remote-1: 20-29, Remote-2: 30-39,
Remote-3: 40-49, Remote-4: 50-59, Remote-5: 60-69)
then press send. If there is more than one
unprogrammed overload, you will need to plug it one at
a time.
Contact Valmetal Automation technician for
this.
The node transfer was successful. The overload will need a power cycle to finish the
programming.
The node transfer was
NOT
successful. Make sure that the node respects the condition and
that overload is powered on.