4FXM70EN - 8/2022
12
2.3 Installing Suction Strainer
Proper eye and skin protection must be worn when
installing and servicing pump.
This pump has been evaluated for use with water only.
Suction tube strainer, dimensions valid for FXM2 only
2.4 Input Power Connections
WARNING!
Electrocution hazard.
Cord connected models are supplied with a grounding
conductor and grounding-type attachment plug.
To reduce risk of electric shock, be certain that it is
connected only to a properly grounded, grounding-type
receptacle.
Disconnect electricity before removing the termination
box cover.
Electrical connections and grounding (earthing) must
conform to local wiring codes.
• Be certain to connect pump to proper supply voltage.
Using incorrect voltage will damage pump and may
result in injury. Voltage requirement is printed on pump
serial label.
• Input power range is 96VAC to 264VAC 50/60 Hz.
• Voltage Selection is automatically detected and adjusted
by power supply. No mechanical switch necessary.
• Use voltage your power cord is rated for.
• Cord connected models are supplied with a ground wire
conductor and a grounding type attachment plug (power
cord). To reduce risk of electric shock, be certain that
power cord is connected only to a properly grounded,
grounding type receptacle.
• Never strap control (input / output) cables and power
cables together.
• Power Interruption: This pump has an auto-restart
feature which will restore pump to operating state it was
in when power was lost.
When in doubt regarding your electrical installation,
contact a licensed electrician.
Power cord installation to the pump:
• Due to regulations Amphenol power cord connection
to the pump (see page 14) has been secured with Loctite
425 thread locking.
• If you have to open this connection, please use a tool,
required max torque is 0.5Nm (4 in.-lbs).
• When installing the cord insert the Amphenol connector
plug into the Amphenol power connector on pump back
side, notice the pin assignment in the connector, see page
14.
• Rotate the connector nut in the cable to secure
connection tightness, use Loctite 425 locking.
Summary of Contents for Flowrox FXM Series
Page 11: ...11 4FXM70EN 8 2022 2 2 Dimensions Dimensions in mm inches in parenthesis FXM2 FXM3 ...
Page 14: ...4FXM70EN 8 2022 14 2 5 WIRING TERMINALS AND I O SCHEMATICS Connector box layout ...
Page 18: ...4FXM70EN 8 2022 18 3 2 Configuration Menu Below is menu structure for Configuration screens ...
Page 23: ...23 4FXM70EN 8 2022 4 Input Setup Below is the menu structure for the INPUT SETUP selection ...
Page 24: ...4FXM70EN 8 2022 24 ...
Page 41: ...41 4FXM70EN 8 2022 11 10 9 8 7 6 5 1 4 3 2 1 5 ONLY WITH 3 8 TUBE NUT CONNECTORS ...
Page 43: ...43 4FXM70EN 8 2022 1 2 3 4 5 6 7 8 9 10 11 ...
Page 45: ...45 4FXM70EN 8 2022 ...