4FXM70EN - 8/2022
32
4.2 Contact Input
Used to remotely start and stop pump using a close=stop
or open=stop signal. If pump should start on an open, then
select “Close: Stop Pump” option. Can be used with an
external foot pedal, a PLC, contact closure, or other similar
external devices.
Default settings: Disable
CC Input Range: 6 – 30 VDC OR
Dry Contact Closure (no voltage required)
Navigate to
Contact Input
menu by MENU button, then
selecting Input Setup, and then
Contact Input
.
Press UP or DOWN arrow to scroll through your options.
Press ENTER to make a selection. You should then notice
radio button (square box) is now filled in next to your
selection.
Press DOWN arrow to scroll down to OK selection. Then
press ENTER.
To navigate back out of menus, select ←Back and press the
ENTER button at bottom of every screen menu until you see
Run Mode screen displayed.
IMPORTANT:
If Contact Closure Input is enabled, pump
will display STANDBY if pump is in Stop mode via the
Contact Closure. Please use caution in this mode. Pump can
Start at anytime. If you must perform maintenance to the
pump, Press STOP button.
When Contact Input is enabled, the word Remote will be
displayed on lower left side of screen at all times
*NOTE: YOU MUST SET THE “CC1 OR CC2” FORMAT
UNDER THE CONDITIONAL LOGIC SECTION 4.5 TO
ENABLE INPUT CONTROL.
Signal stopped pump:
Signal started pump:
4.3 Remote/Local Control
The FXM can be configured for Remote control only, Local
control only, or either (disabled).
When set for Remote control only, all touch pad buttons
except the menu button are disabled. To completely lock
out the menu, configure a password (see page 19, Set
Password). If REMOTE ONLY is selected, the user is
prompted to select an input operating mode which must then
be used when operating the pump.
When set for LOCAL CONTROL only, all input signals
including the remote start/stop are disabled. Note that
the “Contact Closure Input” menu setting (section 4.3) is
switched to “disabled” while
LOCAL CONTROL ONLY
is selected. This menu setting will return to the previous
setting when
REMOTE CONTROL ONLY
or DISABLED is
selected.
Summary of Contents for Flowrox FXM Series
Page 11: ...11 4FXM70EN 8 2022 2 2 Dimensions Dimensions in mm inches in parenthesis FXM2 FXM3 ...
Page 14: ...4FXM70EN 8 2022 14 2 5 WIRING TERMINALS AND I O SCHEMATICS Connector box layout ...
Page 18: ...4FXM70EN 8 2022 18 3 2 Configuration Menu Below is menu structure for Configuration screens ...
Page 23: ...23 4FXM70EN 8 2022 4 Input Setup Below is the menu structure for the INPUT SETUP selection ...
Page 24: ...4FXM70EN 8 2022 24 ...
Page 41: ...41 4FXM70EN 8 2022 11 10 9 8 7 6 5 1 4 3 2 1 5 ONLY WITH 3 8 TUBE NUT CONNECTORS ...
Page 43: ...43 4FXM70EN 8 2022 1 2 3 4 5 6 7 8 9 10 11 ...
Page 45: ...45 4FXM70EN 8 2022 ...