TROUBLESHOOTING

"Bus fault" message is
displayed and the unit
operates at speed 1
(check the fan speed).

• Wiring fault in the carbon dioxide sensor,

in the control panel or in the humidity sen-
sor.

9

• Contact a maintenance company. The connections have to

be checked and corrected if necessary.

"Freezing alert" message is
displayed and the unit is
stopped.

• Antifreezing of the water-circulating ra-

diator is active 

(not in the VALLOX 90 SE unit).

NOTE! If there is no non-freezing solution in the
water of the radiator, the radiator is at risk of
freezing.

10

• Immediately troubleshoot the situation. Find out from a main-

tenance company if there is non-freezing solution in the
radiator. Check if the circulation pump is broken, the boiler
out of operation, etc. The situation may pass by itself as
soon as supply air temperature exceeds 10 degrees, but do
not wait till it happens.

The desired automatic
adjustment does not stay
on.

• There is a fault in the humidity or carbon

dioxide sensor. One of the sensors is bro-
ken or missing.

11

• Contact a maintenance company. The sensor installation

and connections have to be checked. (The sensors are optio-
nal.)

The unit does not work, the
fans are not running and no
indicator light is lit in the
control panel.

• The door switch may be broken, or the

door is possibly not quite closed.

• The unit is out of power, e.g. because a

fuse has blown.

• The glass tube fuse (located in the control

card behind a protecting plate) the electro-
nics inside the unit may have blown.

12

• Check the door switch and fuses. The unit includes a T800

mA glass tube fuse.

• If needed, contact a maintenance company (e.g. to check

the glass tube fuse)

The unit does not obey the
control panel.

13

• Disconnect the plug of the unit from the wall socket, wait for

30 seconds and put the plug back. If this does not help,
contact a maintenance company.

"Carbon dioxide alarm"
message is displayed and the
unit is stopped.

• Carbon dioxide alarm. Carbon dioxide

content has exceeded 5000 PPM for more
than two minutes. May be caused by a
fire.

14

• If there is a fire, take the necessary steps. You can make the

unit operative by disconnecting the plug from the wall
socket, waiting for 30 seconds and putting the plug back
again.

• Check the cleanliness of the filters and the unit. If needed,

clean or replace the filters. Also check the external grille.

15

SYMPTOM

REASON

DO THIS

The filter guard symbol
( ) is displayed and the
unit operates otherwise
normally.

 • The pressure in the filter guard (pressure

difference switch) has risen above the ad-
justment value or speed is 7 or 8.

After a power failure, the unit starts at minimum fan speed.
All the other selected adjustments and setpoints remain in the memory of the unit.

Summary of Contents for 90 SE Series

Page 1: ...AY 1 09 332E 10 4 2009 Code 3520 VALLOX Direct current fan model C326 05 INSTRUCTIONS FOR USE AND MAINTENANCE MODELS VALLOX 90 SE R VALLOX 90 SE L CODE 3520 SUPPLY AND EXTRACT AIR VENTILATION WITH HEA...

Page 2: ...90 SE L With direct current fans VTT certificate number Direct current fan model C326 05 Pre post heating radiator Preheating radiator electric max 900 W standard Post heating radiator electric max 90...

Page 3: ...approximately 45 Humidity content is lower in winter and higher in summer and autumn Dust mites thrive in indoor air if humidity exceeds 50 and if humidity stays at over 60 for a long time in winter...

Page 4: ...eed Ventilation power cannot be set lower than the basic fan speed When carbon dioxide and or relative humidity adjustments are activated power cannot be adjusted higher than the maximum fan speed Whe...

Page 5: ...speed In humidity control fan speed varies between the basic and maximum fan speeds selected When the unit is taken into use for the first time with automatic setpoint search selected factory setting...

Page 6: ...1 Heat recovery bypass function The bypass function tries to get as cool supply air as possible to the ventilation zone by comparing the measuring results of the outdoor air and extract air sensors Th...

Page 7: ...speed for 45 minutes The function is started at the main display of the control panel by simultaneously pressing and holding down the and buttons for 2 seconds The function can also be started at a s...

Page 8: ...ttings menu See manual RH1 35 RH2 40 CO2 0821 PPM Out 20 In 20 Sup 20 Exh 20 Temp setting 20C 5 Scrolling up With this button you can scroll the displays upward 6 Scrolling down With this button you c...

Page 9: ...tment interval for humidity and carbon dioxide adjustments is selected with the and buttons The adjustment interval refers to minutes 3 3 9 Adjustment interval Adjust interval 10 The maintenance remin...

Page 10: ...ure is selected with the and buttons If outdoor temperature is lower than cell bypass temperature the summer winter damper is in the winter position 3 3 15 Changing the operating temperature of heat r...

Page 11: ...lowered back to 4 Move the cursor with the arrow keys and change values with the and buttons Note that Exit and saving are done when the programming is finished by moving the cursor below the word Exi...

Page 12: ...ff before it is possible to start removing the cell When the sealing ledge has been removed the HR cell can be pulled out of the unit Note The laminas of the HR cell are very thin and get easily damag...

Page 13: ...ut Finally disconnect the quick coupling of the fan conductor Removing the extract air fan B The fan is attached to the fixing plate with a butterfly nut Loosen the butterfly nuts and lift the fan out...

Page 14: ...n stop ping and starting See the instructions for using the control panel section 3 3 19 The maintenance reminder symbol is displayed and the unit operates otherwise normally The maintenance reminder...

Page 15: ...l The door switch may be broken or the door is possibly not quite closed The unit is out of power e g because a fuse has blown The glass tube fuse located in the control card behind a protecting plate...

Page 16: ...VALLOX We reserve the right to make changes without prior notification 1 09 332E 10 4 2009 PDF VALLOX 90 SE Vallox Oy Myllykyl ntie 9 11 FI 32200 Loimaa Tel 358 10 7732 200 www vallox com...

Page 17: ......

Reviews: