MOUNTING
Mounting
VALLOX 096 MC has to be mounted in a place where temperature
does not go below +10 °C. Without protective enclosure, the unit
must be located in a place with no acoustic disturbance: storerooms,
technical rooms etc.
Wall mounting
VALLOX 096 MC is mounted on a wall with a mounting plate as
shown in the adjacent fi gure. Make sure that the unit is horizontally
level after mounting.
Wall construction
Observe the wall construction during mounting. Avoid mounting the
unit on a hollow, echoing dividing wall and on a bedroom wall
because of sound conduction, or prevent sound conduction.
Condensing water connections
The delivery includes a water seal. By connecting a pipe to the wa-
ter seal the water condensing from extract air can be led to a fl oor
drain (not directly to the drain). The pipe must not rise after the water
seal. The unit has to be mounted horizontally level, so that conden-
sing water can get freely out of the unit.
5
380
165
433
The minimum distance between the top of the unit and the
fi nished ceiling surface is 30 mm.
162
12
21
20 60
20 30 30
20
60
11
20
30
30
11
84
84
35 30
35
ø7 14kpl
550
30
25
25
Wall mounting plate
30
ϒ
Wall mounting plate
Take into account that the unit
rises during mounting 10 mm
higher than the fi nal height.
Bottom edge
of wall bracket
Pipe outer diameter ø 12 mm
Summary of Contents for 096 MC R