TECHNICAL DATA

Exploded view and parts list VALLOX 096 MC  

(model 3721)

3

1

2

1

2

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

No. Part 

Code

1  Fan assembly 

1108800

2  Fan motor 

935360

3  Wall mounting plate 

3080700

4  Water seal 

3292500

5  G4 coarse fi lter supply air 

978044

6  Filter stand supply air 

3464400

7  F7 fi lter 

978220

8  HR cell 

933260

9  Upper support for HR cell 

3467200

10  Filter stand extract air 

3464500

11  G4 coarse fi lter extract air 

978045

No. Part 

Code

12  Bypass duct assembly, handedness must be indicated 

3475100

13  Damper motor 

930621

14  Extract air outlet 

985026

15  Motherboard MC 

949035

16  Safety switch 

948370

17  Post-heater, R-model unit 

942210

 

Post-heater, L-model unit 

942211

18  Door assembly 

3475200

19  Door latch assembly 

3355900

20  NTC sensor, sensor number must be indicated 

946140

21  Glass tube fuse 5x20 0.4 A slow 

952485

Summary of Contents for 096 MC R

Page 1: ...ow L model unit Adjustment of supply air heating 12 SC controller Code 3721 Models VALLOX 096 MC R VALLOX 096 MC L Operating maintenance and technical instructions Electrical connection 230 V 50 Hz 5...

Page 2: ...peration in dwellings and detached houses The winter function parameters can be adjusted for extreme conditions such as a swimming bath but even then it is advisable to contact Vallox Maintenance Adju...

Page 3: ...he HR cell is faulty Check the sensor and conductors replace if needed 2 Extract air sensor is faulty Check the sensor and conductors replace if needed 3 Supply air sensor is faulty Check the sensor a...

Page 4: ...ed with a coarse filter C By using original Vallox filters you ensure good operation of the ventilation unit and the best filtering result The replacement interval of lters depends on dust content in...

Page 5: ...f the extract air duct G figure 1 and then remove the stopper screw from the lower edge of the duct After that the extract air duct comes out by turning and simultaneously pushing downwards gures 2 an...

Page 6: ...You can check it by pouring a little water in the tank Clean if needed Do not let water ow into electrical devices VALLOX We reserve the right to make changes without prior notice Extract air fan Cond...

Page 7: ...8V 4 5V 6 0V 7 0V 7 7V 9 0V 10 0V 11 35V 2 8V 4 5V 6 0V 7 0V 7 7V 9 0V 10 0V 11 35V Air flow dm3 s 10 6 25 2 38 1 46 6 53 8 65 6 72 9 76 0 12 0 27 6 36 7 44 2 50 5 61 0 70 4 76 4 Medium frequency of...

Page 8: ...o safety switch SLO Phase voltage to circuit board from safety switch SNO Zero voltage to circuit board from safety switch SFL Phase voltage to supply air fan SFN Zero voltage to supply air fan EFL Ph...

Page 9: ...hollow echoing dividing wall and on a bedroom wall because of sound conduction or prevent sound conduction Condensing water connections The delivery includes a water seal By connecting a pipe to the...

Page 10: ...into the thread bars and lift the ceiling mounting plate in place Then push a rubber damper and washer to each thread bar all the way into the cup of the plate and turn the nut Shorten the lower ends...

Page 11: ...supply air 978044 6 Filter stand supply air 3464400 7 F7 filter 978220 8 HR cell 933260 9 Upper support for HR cell 3467200 10 Filter stand extract air 3464500 11 G4 coarse filter extract air 978045...

Page 12: ...1 09 601ENG 5 11 2014 PDF...

Reviews: