180-PE1006 v1.11
October 3, 2018
Page 14
PE1006
INSTALLATION INSTRUCTIONS
MINIMUM CLEARANCES for PE1006 and PEJ1006
Residential Installations
A
B
C
D
E
F
J
Roof exit, parallel and corner. No fan kit required.
16”
407 mm
9”
230 mm
29.5”
750 mm
19.25”*
489 mm
14”
360 mm
28”*
712 mm
49”
1245 mm
Roof exit, reduced side. Use side shields.
10”
254 mm
9”
230 mm
23.5”
597 mm
19.25”*
489 mm
49”
1245 mm
Roof exit, reduced corner. Use side shields and either fan kit or rear
shield.
6”
153 mm
20”*
508 mm
49”
1245 mm
Roof exit, close clearance. Use side shields, and either fan kit or
rear shield.
10”
254 mm
6”
153 mm
23.5”
597 mm
16.25”*
413 mm
49”
1245 mm
Wall exit, parallel and corner. No fan kit required.
16”
407 mm
9”
230 mm
29.5”
750 mm
19.25”*
489 mm
14”
360 mm
28”*
712 mm
49”*
1245 mm
Wall exit, reduced side. Use side shields.
10”
254 mm
9”
230 mm
23.5”
597 mm
19.25”*
489 mm
49”*
1245 mm
Wall exit, reduced corner. Use side shields and either fan kit or rear
shield.
7”
180 mm
21”*
535 mm
49”*
1245 mm
Alcove, roof exit. Use side shields, and either fan kit or rear shield.
10”
254 mm
6”
153 mm
23.5”
597 mm
16.25”*
413 mm
49”
1245 mm
Mobile Home Installation
Roof exit, parallel and corner. Use side shields, either fan kit or rear
shield and outside air kit.
10”
254 mm
6”
153 mm
23.5”
597 mm
16.25”*
413 mm
6”
153 mm
20”*
508 mm
49”
1245 mm
* Check with local codes and pipe manufacturer for pipe clearances. In Canada, 18” clearances from single wall pipe is required.
G = 3” (76mm) in USA
8” (203mm) in Canada
H = 16” (406mm) in USA
18” (456mm) in Canada
I = 0” (0mm) in USA
8” (203mm) in Canada
K = 18” (456mm) for single wall pipe in Canada
Ember protection shield (not required to have an insulation value)
is to be listed under UL 1618-2009 (type 1) and must have a minimum size of:
In USA: 33” x 42 3/8” (839 x 1077 mm)
In Canada: 43” x 52 3/8” (1093 x 1331 mm)
Min. Alcove minimum width 47”, maximum depth 48”, minimum height above stove top 49”
This stove must be installed in compliance with all local codes and regulations.
Summary of Contents for Blaze King PRINCESS PE1006
Page 46: ...180 PE1006 v1 11 October 3 2018 Page 46 PE1006 REPLACEMENT PARTS Princess Classic PE1006BK...
Page 47: ...180 PE1006 v1 11 October 3 2018 Page 47 PE1006 REPLACEMENT PARTS Princess Parlor PE1006LBK...
Page 49: ...180 PE1006 v1 11 October 3 2018 Page 49 PE1006 REPLACEMENT PARTS...
Page 50: ...180 PE1006 v1 11 October 3 2018 Page 50 PE1006 REPLACEMENT PARTS...
Page 51: ...180 PE1006 v1 11 October 3 2018 Page 51 PE1006 REPLACEMENT PARTS Princess Classic Brick Layout...
Page 57: ...180 PE1006 v1 11 October 3 2018 Page 57 PE1006 NOTES...
Page 58: ...180 PE1006 v1 11 October 3 2018 Page 58 PE1006 NOTES...
Page 59: ...180 PE1006 v1 11 October 3 2018 Page 59 PE1006 NOTES...