201
Thermo H plus
2 Technical data
2
Technical data
Except where limit values are specified, these technical
data refer to the usual heater tolerances of ±10% at an
ambient temperature of +20°C and at the rated voltage.
Technical data:
Heater (general)
Kind of design
Hybrid heater
Ambient temperature during operation
°C
-40 up to +85
Storage temperature
°C
-40 up to +85
Operating overpressure max.
bar
2.0
Dimensions (tol/- 3 mm)
mm
Lenth: 710
Width: 300
Height: 350
Weight
kg
32
Capacity of the heat exchanger
l
7
Minimum water flow
l/h
>1500 *
Minimum capacity of the water system
l
35
Antifreeze ratio in the cooling system
%
30 up to 60
* Depending on the heat flow taken by the vehicle, a minimum burner operation
of 120 seconds should be achieved.
Electrical part (high voltage)
Device version
AC070 AC090 AC140 AC200 DC070 DC070 DC200 DC140
Nominal heating flow max. kW
7
9
14
20
7
7
20
2x 7
Rated voltage
V
400
690
600
690
600
Rated control voltage
V
24
Control voltage min.
V
20.4
16
Control voltage max.
V
26.4
32
Power consumption
kW
7
9
14
20
7
7
20
2x 7
Frequency
Hz
50-60
--
Rated current
A
9.9
13.5
19,75
29.6
9.9
11.8
29.6
2x 11.8
Electrical protection
A
16
16
25
32
16
16
35
2x 16
Summary of Contents for Thermo H 160