25
Safety thermostat
All Valentine fryers are fitted with a safety thermostat for each tank. These safety thermostats
are placed in the heating element box at the back of the fryer. The red reset button [15] goes
up underneath the housing.
It is triggered:
•
when the oil temperature exceeds 230°C
•
when the capillary tube is damaged
•
when the temperature falls below 0°C
or when the appliance is not being used properly:
•
when it is being heated without oil or the oil level is too low
•
when it is being drained without triggering the switch
•
when a block of fat is being melted directly on the heating element
To reset the fryer:
•
Stop the fryer
(thermostat switch [1] to Pos. "0")
•
Allow the fryer to cool down
(to speed this process up lift the heating element and
place it on the lid). Until the thermostat bulb [13] attached to the heating element cooled
down, you cannot reset the safety thermostat
•
Press down firmly on the red button
[15] (until you hear the "click")
Problems and faults
Problem
Probable cause
Action
The fryer is not heating.
•
No power
•
Safety thermostat has been
triggered
•
Housing not properly in place
•
Carefully check the fuses, plug
and socket
•
Reset it (see above)
•
Check that the housing is in the
correct position
The fryer is not heating suffi-
ciently
•
One phase is missing
•
Heating element is faulty
•
Check the fuses
•
Call the after
-
sales service team
The control lamp does not light
up or flashes
•
Faulty control lamp
•
One phase is missing
•
Change the control lamp
•
Check the fuses
The control lamps light up but
the fryer does not heat up
•
Heating element is faulty or the
thermostat is faulty
•
Call the after
-
sales service team
Other fault
•
Call the after
-
sales service team
Summary of Contents for TF55
Page 12: ...39...
Page 13: ...40...
Page 14: ...41...
Page 15: ...42 TF5 2x400V 3 6kW 9A TF55 3x400V 7 2kW 16A TF5 55 1x 2x 1N230V 1x 2x 3 6kW 1x 2x 16A...