AUS

  

1300 734 253     NZ  0800 734 253

SOFTWARE

Main Icons

With the main icons, you can do the following: 

Download Measurements

Test Report

Opens a test report window

Read USB Flash Drive

Open

Open a measurement from pendrive

Save

Save the measurement

Close

Help

This screen

Exit

These are the small icons, in the upper part of the main window. 

Measurement Window

After downloading the measurement data, it appears in a new window which includes the discharge curve. You can see the 

filename in the upper right corner of the window. 

With the small icons, you can do the following:

Original Size

Restore original size

Zoom

Zoom any part of the curve

Activate Vertical Marker

Move the marker with buttons

Activate Mouse Marker

Move the marker with mouse

Details

Shows the test result in a small window

Setting U, I taxers

Time

Current

Voltage

There are other fields. Here you can enter the values of the axes. You can write the current voltage and time values. Using 

this feature, you can only see the desired part of the graph. It is useful in case of long curves. 

Summary of Contents for BACA 24V25A

Page 1: ...AUSTRALIA 1300 734 253 sales valen com au www valen com au NEW ZEALAND 0800 734 253 sales valen co nz www valen co nz OPERATION MANUAL BATTERY CAPACITY AND CHARGER ANALYSER BACA 24V25A Version 6 0...

Page 2: ...ry increasing growth the Lake Cargelligo Head Office moved into a brand new purpose built facility in 2012 In 2015 Regal Electro successfully completed its rst ENLiFEN Energy Storage Optimiser ESO pro...

Page 3: ...done Upbeat Positive Attitude If our employees have a positive attitude and constantly strive to give your best effort eventually we will overcome our immediate problems and nd you are ready for grea...

Page 4: ...under test Easy to use software allows for data and tests from the BACA to be stored exported to PDF or printed for the analysis of batteries The BACA 12V and 24V unit can complete up to 200 cycles un...

Page 5: ...the DISPLAY CHANGE button 1 Voltage Screen Voltage 12 8V 2 Test Parameter Screen Test parameters 3 Read Test Results Read test result 4 Charge Charge 5 Discharge Discharge 6 Pendrive Suspend PNDRV Sus...

Page 6: ...off voltage screen Disch Currebt 5 5A Set the cut off voltage Volts or VPC between 6V to 15V with 0 3V steps 0 05VPC step U Cut Off 1 2V c Enter 07 2V After setting the cut off voltage press the DISPL...

Page 7: ...If the battery is fully charged you can start the test with discharging In this case the first cycle is a half cycle there is no charged Ah you will see only discharged Ah when reading the test result...

Page 8: ...ndrive or disconnecting the battery from the tester during the test will cause the loss of test data of the entire test ERROR MESSAGES No Pendrive 000 this indicates that there is no USB connected to...

Page 9: ...a new window which includes the discharge curve You can see the filename in the upper right corner of the window With the small icons you can do the following Original Size Restore original size Zoom...

Page 10: ...3 With the RIGHT mouse button you can place voltage or current markers to any point of the graph 4 Print the test report Add in your company and contact details Fill in the name place of measurement a...

Page 11: ...the actual curso position Time Value Time value at the actual cursor position GRAPH SETTINGS The measurement window contains a graph setting icon If you click on the icon you will have the visisble p...

Reviews: