FP16
– Saint-Laurent - Installation and Operation Manual
7
1.1.1
Regulations Covering Fireplace Installation
When installed and operated as described in this manual, the FP16 Saint-Laurent wood fireplace is suitable
for use as a fireplace appliance in residential installations.
In Canada, the CSA B365 Installation Code for Solid Fuel Burning Appliances and Equipment and the CSA
C22.1 Canadian National Electrical Code are to be followed in the absence of local code requirements. In
the USA, the NFPA 211 Standard for Chimneys, Fireplaces, Vents and Solid Fuel-Burning Appliances and the
ANSI NFPA 70 National Electrical Code are to be followed in the absence of local code requirements.
PLEASE NOTE
The Fireplace is not approved for use with a so-
called “positive flue connection” to the clay tile of a
masonry chimney.
1.2
General Information
1.2.1
FP16
–
Saint-Laurent Wood Fireplace Specifications
Table 1: FP16 - Saint-Laurent Specifications
Fuel Type
Dry cordwood
Test Standards (safety)
ULC-S610 and UL 127
Recommended Heating Area
< 1,000 sq. ft. (< 93 m
2
)
Minimum burn rate
> 5 kg/h (> 11 lb/h)
Shipping Weight
765 lb (347 kg)
Firebox Volume
6.4 cu.ft.
Maximum Log Length
30" east-west
Flue Outlet Diameter
8" (203 mm) diameter
Mobile home approved
No