![Valcourt FP16 Saint-Laurent Installation And Operation Manual Download Page 33](http://html1.mh-extra.com/html/valcourt/fp16-saint-laurent/fp16-saint-laurent_installation-and-operation-manual_3209604033.webp)
FP16
– Saint-Laurent - Installation and Operation Manual
33
This wood fireplace is to be connected to a chimney with an 8” diameter fl
ue passage.
The fireplace may also be connected to a masonry chimney, provided the chimney complies with the
national or local building code. The chimney must have either a clay liner or a listed stainless steel liner. If
the masonry chimney has a square o
r rectangular liner that is larger in cross sectional area than a round 8”
flue, it should be reduced by relining
with a listed 8” stainless steel liner. Do not downsize the flue to less
than 8”
.
TABLE 4 : LISTED CHIMNEYS FOR YOUR FP16 - SAINT-LAURENT WOOD FIREPLACE
WARNING
•
IN EVERY CASE, THE CHIMNEY MUST START WITH A 8'' DIAMETER ANCHOR PLATE SECURED TO THE
FIREPLACE. (SOLD SEPARATELY)
•
IF THE MALE NOZZLE (A) OF THE ANCHOR PLATE
EXCEEDS 2" (51 MM) IN LENGTH (SEE IMAGE BELOW),
IT SHALL BE CUT ABOVE THE LIFTING HOOKS WELDED
TO THE INSIDE OF THE FLUE OUTLET SO THAT THE
ANCHOR PLATE RESTS PERFECTLY ON TOP OF THE
FIREPLACE.
•
IF THE FLUE OUTLET IS CUT ONLY AROUND THE
HOOKS, MAKE SURE THAT THE FLUE DAMPER
MECHANISM WORKS PROPERLY BEFORE CLOSING
THE WALLS.
CHIMNEY MANUFACTURER
BRAND
TYPE
INNER DIAMETER
Olympia Chimney
Ventis
1" Solid Pack
8" (20 cm)
SBI Venting division
Nexvent
1" Solid Pack
8" (20 cm)
Selkirk
CF Sentinel (CF)
2" Solid Pack
8" (20 cm)
Selkirk
Super Pro 2100 (ALT)
2" Solid Pack
8" (20 cm)
Selkirk
Super Vent 2100 (JM)
2" Solid Pack
8" (20 cm)
Security Chimney
S-2100 +
2" Solid Pack
8" (20 cm)
M&G DuraVent
Dura Plus HTC
2" Solid Pack
8" (20 cm)
M&G DuraVent
Dura Plus
AC Triple Wall
8" (20 cm)
American Metal
HSS
AC Triple Wall
8" (20 cm)
American Metal
HS
AC Triple Wall
8" (20 cm)