FP10 Lafayette - Installation and Operation Manual
73
7.
When
passing
through
a
combustible
wall
or
floor,
a
firestop
must
be
installed
at
the
wall
or
floor
penetration.
The
hole
size
must
be
in
accordance
with
the
duct
manufacturer’s
instructions.
8.
Do
not
connect
the
hot
air
ducts
to
a
central
heating
system.
Malfunction
of
the
heating
system’s
fan
will
cause
the
fireplace
to
overheat.
9.
Do
not
use
insulated
flexible
ducts
as
they
may
overheat.
10.
Do
not
use
tees
or
any
other
components
than
the
ones
specifically
listed
here.
11.
All
ducts
must
extend
upwards
or
horizontally.
Never
route
the
ducting
downwards.
12.
The
hot
air
outlet
grilles
must
be
installed
with
the
louvers
pointing
downwards
in
order
to
prevent
overheating
adjacent
ceilings.
13.
Always
install
the
two
outlet
grilles
when
using
the
hot
air
outlet
kit
and
blocking
the
upper
louver
of
the
fireplace.
Summary of Contents for FP10 Lafayette
Page 9: ...FP10 Lafayette Installation and Operation Manual 9...
Page 10: ...10 FP10 Lafayette Installation and Operation Manual...
Page 11: ...FP10 Lafayette Installation and Operation Manual 11...
Page 37: ...FP10 Lafayette Installation and Operation Manual 37...
Page 95: ...FP10 Lafayette Installation and Operation Manual 95 APPENDIX 7 EXPLODED DIAGRAM AND PARTS LIST...