45
Reference
in
Figure
42
.
Parts required. (The numbers in
brackets are the parts numbers used
by Security Chimneys)
Inner diameter 6
″
Inner diameter 7
″
1
″
insulation
(ASHT+)
2
″
insulation
(S2100+)
1
″
insulation
(ASHT+)
2
″
insulation
(S2100+)
A
Anchor Plate (6SP)
R
NR
R
R
A
Anchor Plate (6XSP)
NR
R
NR
NR
B Screws
R R R R
C 6
″
à 7
″
Chimney adaptor
(6AW7)
NR NR R R
D 7
″
Chimney adaptor, 1
″
insulation to 2
″
insulation
(7UCA)
NR NR NR R
TABLE 3 – LIST OF MANDATORY COMPONENTS
CHIMNEY
MANUFACTURER
MANDATORY COMPONENTS
TYPE/BRAND
Selkirk
Ventilated roof flashing.
Must have rafter protectors at the roof level if
the chimney is enclosed at the attic level (see
section 4).
Ultra-Temp (UT),
Super Pro (SPR),
Super vent (JSC), Hart
& Cooley (TLC),
Sure-Temp (ST)
Security Chimney
Rafter protector at the roof level if chimney is
enclosed at the attic level (see section 4).
Requires insulated attic radiation shield unless
chimney is enclosed at the attic level.
Requires the use of a 6AW7 (Solid pack 1")
adapter for a ASHT+ of 7".
Requires the use of a 6AW7 and a 7UCA
adapter for the S-2100 of 7".
1" Solid Pack:
ASHT+,
2" Solid Pack : S-2100
Simpson Dura-Vent
Ventilated roof flashing.
Rafter protector at the roof level is chimney is
enclosed at the attic level (see section 4).
1" Solid Pack :
Dura Tech
ICC
Ventilated roof flashing.
Rafter protector at the roof level if chimney is
enclosed at the attic level (see section 4).
Excel 2100
American Metal
Chimney cannot be enclosed at the attic level.
AC Triple wall HS,
AC Triple wall HSS