4.3 Video parametres
Video formats:
JPG, MJPG, H.263, H.264
Video for WEB:
I
nternet Explorer,
Mozilla, Opera, Firefox…
- (set of JPG pictures - Port 80)
it is used repeated
http request „IPadresa/video.jpg“
programm PopUp
(UDVguard) - (MJPEG stream - Port 80) is used http
request „IPadresa/video.mjpg“ (sometimes is reload necessary to run).This
video is more fluent and has less network strain.
Stream video for IP phones:
H.263 and H264 is established by IP BOLD door entry and IPvideo phone over
SIP/SDP protocol on standard SIP port. The video (as same as sound) then
runs by RTP protokol on ports agreed over SIP (usually 9078).
rtsp request „rtsp://IPadress/video.264“
or
rtsp request „rtsp://IPadress/video.263
Video parametres:
JPG Pictures are created in IP modul and for all transmit protocols are the
same .The Size (resolution) of video is selected in "Video setting" on WEB.
Maximal resolution is defined by USB camera type and mostly is 640x480
Stream H.263 knows CIF resolution (352x288). It means bigger JPEG is cut
and smaller framed.
Frequency (1-15 picture./sec) JPG Picture is selected in "Video setting" on
WEB.
Frequency MJPG and Stream H.263 coming from camera. It is used every
second and reset is between 7-15 pictures/sec. Higher resolution brings
decreasement of Pictures/ sec. (limited by processor efficiency)
Ports:
Port
80
for http (WEB pages even JPG / MJPG video on them)
Port
5060
for SIP
Ports RTP with oposite party communicates over SIP. Usually Port
7078
suggested for audio and Port
9078
for video
Port
554
video( H264 and H263) provided by door entry (server) protocol RTSP
Audio files:
WAV
– 8Kbit – mono – 16bit PCM
Setup:
Default IP adress 192.168.1.250
name: admin / password: 1234
Telnet:
name: root / password: 8765
Summary of Contents for IP bold series
Page 2: ......
Page 9: ...IP BOLD installation and operating instructions 9 IP BOLD TK1C IP BOLD TK4C...
Page 12: ...IP BOLD installation and operating instructions 12...
Page 15: ...IP BOLD installation and operating instructions 15...
Page 19: ...IP BOLD installation and operating instructions 19 1 5 2 Montage dimension...
Page 77: ......