Permitted
– relay function might be eliminated. Due this will be eliminated
synchronization signal for other relays. Meaning is for example when
you want temporarily prevent certain door opening. Then instead of
all codes cancellation and their repeated programming simply prohibit
this relay. After time out you can easily return relay with all codes to
original function. When such status repeats regularly (for example
school) you can use time plan.
Time plan
– defines time period when relay is working and hen not. For
example is shop operation time , school, etc..
Relay mode monostable
– by code is closed and after preprogrammed
timeout is open. Using for electrical lock switching, sliding gates
control, button press signalling etc... (for control codes setting you
must insert
„ON” (via follow)
Relay mode bistable
– by code is closed and stay closed till moment of open
by other code. For this purpose is beside control codes posibility
select „ON” for closing and „OFF” for open. (via follow)
Delayed closing
– is time, between closing code evaluation and relay closing.
It has no influence for open code which is performed immediately.
Closing time is calculated from real relay closing. Using is for
example:
progressive door opening, we setup same closing code for
both relays, by this delay is monitored walking time from first to
second doors.
This feature is adjustable by synchronization as well.
By synchronization delay are available individual codes for each
doors control.
Closing time
– relay closing time in monostable mode (time of electrical lock
opening)
Synchronize with time plan
- it is selected time plan for relay and 2 options
are available:
Monostable, then allways when setup time period in time plan is
suitable and time plan is active is perform closing for preprogrammed
closing time.
Bistable, then allways when setup time period in time plan is suitable
and time plan is active the relay is closed and out of those conditions
is open.
Synchronize with relay 1
– 4
– relay closing starts closing of the same or
other relay. Example for usage is sliding gate control, where by partly
opening you can create passage
– door substitution. For this mode
relay must close for 1 sec in 2 times in sequence. Where period
between closing is created passage.( for example 6sec).
The setting
make that for relay 1 select monostable mode with time closing 1 sec,
synchronization with relay 1 and synchronization delay 7 sec
. In case
you need setup situation that for one code (55) relay 1 close 2 pulses
in sequence
– passage creation and by second code (56) gate will be
closed then use not connected relay 4 for synchronization.
Setting of
relay 1 is monostable, closing time 1 sec, synchronization with relay 4
Summary of Contents for IP bold series
Page 2: ......
Page 9: ...IP BOLD installation and operating instructions 9 IP BOLD TK1C IP BOLD TK4C...
Page 12: ...IP BOLD installation and operating instructions 12...
Page 15: ...IP BOLD installation and operating instructions 15...
Page 19: ...IP BOLD installation and operating instructions 19 1 5 2 Montage dimension...
Page 77: ......