7-1
ValcoMelton.
SECTION 7 - SPECIFICATIONS
SECTION 7 - SPECIFICATIONS
SECTION 7 - SPECIFICATIONS
SECTION 7 - SPECIFICATIONS
SECTION 7 - SPECIFICATIONS
These charts are basic guidelines for
the general systems available. Due to
configuration changes and options,
your specific system may vary slightly.
The Valco Installation Specialist can
answer any questions you may have
regarding your specific system setup.
LLD Alarm System
:
Width:
7"
Height:
14.5"
Depth:
5.5"
LLD probe inputs:
Warning level: activates flashing light and relays
Low-limit level: activates audio alarm
LLD Alarm system outputs:
Switched 115/230VAC, 1/0.5A, 50/60Hz—switched off when
warning level (or lower) is reached
Dry contacts, form C (1 N.O. I.N.C.), 230VAC, 1A maximum
LLD AutoRefill System
:
Width:
7"
Height:
14.5"
Depth:
5.5"
LLD probe inputs:
Low-limit level: activates automatic refilling of glue
LLD AutoRefill system outputs:
Switched 115/230VAC, 1/0.5A, 50/60Hz—switched off when
warning level (or lower) is reached
Dry contacts, form C (1 N.O. I.N.C.), 230VAC, 1A maximum
Summary of Contents for LLD
Page 4: ......
Page 8: ...1 2 ValcoMelton Section 1 Introduction MC036 Low Level Detection Alarm AutoRefill Systems ...
Page 38: ...5 2 ValcoMelton Section 5 Maintenance MC036 Low Level Detection Alarm AutoRefill Systems ...
Page 40: ...6 2 ValcoMelton Section 6 Troubleshooting MC036 Low Level Detection Alarm AutoRefill Systems ...
Page 42: ...7 2 ValcoMelton Section 7 Specifications MC036 Low Level Detection Alarm AutoRefill Systems ...
Page 56: ......