3-9
ValcoMelton
Section 3 - Installation
MC036 - Low Level Detection Alarm/AutoRefill Systems
The main power supply must be 115/230 VAC, 50/60 Hz, 2/1 A. The 115/230
power requirement is field-switchable. The power module accepts a standard
IEC line cord (supplied).
To connect the line cord, follow these steps:
1.
Attach the line cord clamp to the bottom surface of the control
box, using the two screws on either side of the power module.
2.
Insert the line cord into the power module
3.
Tighten the line cord clamp to prevent inadvertent loss of power.
The line cord supplied can either be
directly wired to a branch circuit or (with
the proper plug type) plugged into a
115 or 230 VAC outlet socket. The wire
colors of the supplied line cord are as
follows:
Wire Type
International Line Cord Color
North American Line Cord Color
Line Brown
Black
Neutral Blue
White
Ground Green/Yellow
Green
Electrical Installation of
the Control Box