User’s Guide ______________________________________________________________________
198 _________________________________________________________________ M211840EN-C
permits a response to an M command to be sent within a 380 ms
window.
-
Sensors must return to a low-power standby mode after receiving
an invalid address or after detecting a marking state on the data line
for 100 ms (tolerance: +0.40 ms).
-
When a recorder addresses a different sensor, or if the data line has
been in the marking state for more than 87 ms, the next command
must be preceded by a break.
NOTE
The low-power standby mode, in addition to being a low-power
consumption state, is a protocol state and it takes a moment to leave
that state.