Bit
Message
Probable cause
Actions
17-31
Reserved for future use
−
−
1)
Bit is shown in MD30 interface response data message, not in RoadAI.
2) Reported by MD30 models that have the window contamination feature.
Table 5 Status information
Bit
Message
Value
Description
0
Not ready to measure
0
= Ready
1
= Not ready
Unit is starting up. When unit
reaches full operational status, the
flag is cleared. Measurement data
may be invalid.
If the condition persists, check
error bits.
1
Reference setting ongoing
0
= Not ongoing
1
= Ongoing
If reference setting does not start,
check status information bits
10 ... 13 and error bits.
2
Laser temperature change in
progress
0
= Not ongoing
1
= Ongoing
Unit operational, but
measurement data may be invalid.
Wait for laser temperature change
to finish.
If the condition persists, check
error bits.
3
Window contamination warning
0
= OK
1
= Contaminated
Window is getting contaminated.
Clean the window.
4
Window heating
0
= OK
1
= Not working
If heating is not working, monitor
window contamination.
5
Low input voltage detected
0
= Voltage OK
1
= Voltage low
Unit operational, but check input
voltage.
6
High input voltage detected
0
= Voltage OK
1
= Voltage high
7
High internal temperature
detected
0
= Temperature OK
1
= Temperature high
First notification of unit getting
too hot.
8
Temperature unit
0
= °C
1
= °F
−
9
Layer thickness unit
0
= mm
1
= inch
−
10
Reference setting interrupted due
to laser temperature change
0
= False
1
= True
Repeat reference setting when
laser temperature change has
finished.
11
Reference setting interrupted due
to hardware error, check
parameter
0x56
0
= False
1
= True
Check error bits and parameter
0x56
, which contains reason for
error.
12
Reference setting values are not
updated due to poor signal quality
0
= False
1
= True
Excessive variation in road surface
type. Find more representative
road surface.
Reference Guide
M212309EN-C
9