HMD70U/Y Operating Manual 

M210277EN-C 

 

TECHNICAL DATA 

Relative humidity 

Measurement range 

0...100 %RH 

Accuracy at 20 

°

     

 

 
Temperature dependence 

 

 
Response time (90%) 
at +20 

°

C in still air 

15 s with membrane  

 

filter 

Humidity sensor 

INTERCAP 15778HM 

 

Temperature (Y

 

model only) 

 
Measurement range 

-20...+80 

°

C  

Accuracy 

  

 

 
Linearity 

better than 0.1 

°

Temperature sensor 

Pt 1000 IEC 751class B 

 

General 

 
Supply voltage range depends on  the selected output 
signal. When AC supply is used, an isolated source is 
recommended. The current outputs require an 
optional output module, part no. 18945HM. 
 

DC 

AC 

0...1 V 

10...35 V    9...24 V 

0...5 V 

14...35 V  12...24 V 

0...10 V 

19...35 V  16...24 V 

0...20 mA (RL = 0 

10...35 V  11...24 V 

0...20 mA (RL = 500 

20...35 V  17...24 V 

 
Factory setting 0...1V. Other outputs selectable by 
jumper connections. An output change causes an error 
which is less than 0.5 %RH without recalibration. 
 
 
 
 
 
 

Operating temperature range: 
electronics 

-5...+55 

°

 

sensor head 

-40...+80 

°

 
Storage temperature range 

-40...+80 

°

Housing: 
sensor head 

stainless steel 

electronics housing 

cast aluminium 

Cable glands 

 

bushing 

for 7...10 mm (PG9) 

 

cable (housing IP65/  

 

NEMA 4), 

 

part no 18941HM 

or armoured cable glands 

part no 10528HM 

Sensor protection: 
standard 

membrane filter 

 

(part no. DRW010525) 

option 

stainless steel sintered 

 

filter 

 

(part no. HM46670) 

Connections 

screw terminals 

 

0.5...1.5 mm2

 

 

Electromagnetic compatibility

  

 
The emission and immunity tests have been 
performed according to standard EN 61326-1:1997 + 
Am 1:1998, Electrical equipment for measurement, 
control and laboratory use- EMC requirements; Light 
environment. 
 

Emissions: 
Test 

 

Radiated interference 

CISPR16,  class B 

 
Immunity: 
Test

         

            

Setup according to

     

 

 
Electrostatic discharge  

EN/IEC 61000-4-2       

Electrical fast transients  

EN/IEC 61000-4-4 

RF-radiated fields           

EN/IEC 61000-4-3      

*GSM-field immunity     

ENV50204:1995, 
criteria A 

(*additional test) 
 

GUARANTEE

 

Vaisala issues a guarantee for the material and 
workmanship of this product under normal operating 
conditions for one year from the date of delivery. 
Exceptional operating conditions, damage due to 
careless handling or misapplication will void the 
guarantee. 
 
 
Vaisala Oyj 

 

Vanha Nurmijärventie 21,  
FI-01670Vantaa, Finland 
 

  

 

Summary of Contents for HUMICAP HMD70U

Page 1: ...urface and drill the holes as indicated Remember to drill an additional hole for calibration purposes The calibration can be conveniently performed on site with the HMI41 or HM70 indicator equipped wi...

Page 2: ...D70U Y transmitter Controller VAC VAC Us GND signal RH T GND Us RH T signal HMD70U Y transmitter Figure 4 The recommended AC connection HMD70U Y transmitter HMD70U Y transmitter Controller shared comm...

Page 3: ...racy is recommended to be checked at least once a year the interval depends on the operating conditions and the required accuracy of the measurement When checking the transmitter calibration use the H...

Page 4: ...or head stainless steel electronics housing cast aluminium Cable glands bushing for 7 10 mm PG9 cable housing IP65 NEMA 4 part no 18941HM or armoured cable glands part no 10528HM Sensor protection sta...

Page 5: ...ehen Sie eine zus tzliche Bohrung f r Kalibrierungen vor Die Kalibrierung l t sich sehr bequem mit dem Hand me ger t HMI41 einer entsprechenden Sonde und einem optionalen Kalibrier kabel durchf hren E...

Page 6: ...T GND HMD70U Y GND Us RH T Abbildung 4 Empfohlener AC Anschlu gemein samer Leiter Signal HMD70U Y HMD70U Y Signal Us RH T RH T Us GND GND 24 VAC Steuerger t Abbildung 5 Bildung einer gemein samen Sch...

Page 7: ...keit der Transmitter sollte wenigstens einmal im Jahr berpr ft werden die erforderlichen Kalibrier intervalle h ngen im wesentlichen von der Einsatzumgebung sowie der geforderten Me genauigkeit ab Die...

Page 8: ...l Elektronikgeh use Aluminium Druckgu Kabelverschraubung f r 7 10 mm PG9 Kabeldurchmesser Geh useschutzart IP65 NEMA 4 Teil Nr 18941HM oder Sonderausf hrung f r amierteErdkabel Teil Nr 10528HM Sensors...

Page 9: ...ercez les trous comme indiqu Une calibration du transmetteur peut tre effectu e ais ment sur le site gr ce l indicateur portable HMI41 quip de la sonde appropri e et le c ble de calibration en option...

Page 10: ...ANDE A PAS DE BOUCLE DE COURANT RECOMMANDE signal signal signal 24 VAC 24 VAC Us RH T GND HMD70U Y GND Us RH T HMD70U Y HMD70U Y signal Us RH T RH T Us GND GND 24 VAC Sch ma 4 Connexion AC recommand e...

Page 11: ...de v rifier la pr cision une fois par an cette fr quence d pend des conditions de fonctionnement et de la pr cision de la mesure requise Pour v rifier la calibration du transmetteur utilisez l indicat...

Page 12: ...ectroniques 5 55 C du capteur 40 80 C Gamme de temp rature de stockage 40 80 C Mat riau du capteur inox du bo tier de l lectronique aluminium Passage du c ble de la sonde presse toupe r f 18941HM ou r...

Page 13: ...HMD70U Y M210277EN C 13 HMD70U HMD70Y 100 3 94 100 3 94 82 3 23 82 3 23 250 9 84 62 2 44 12 0 47 1 HMD70U Y HMD70U Y HMI41 HM70 2 18941HM 18941HM 2...

Page 14: ...M210277EN C 14 1 3 0 1 0 5 0 10 T RH RH RH RH T T T T RH RH T 1 1 1 1 2 3 4 5 0 20 U U U U Us T RH 0 20 RH T 18945HM 2 3 HMD70U Y Us RH T Us RH T HMD70U Y 4 HMD70U Y HMD70U Y Us Us RH T RH T 5 HMD70U...

Page 15: ...HMD70U Y M210277EN C 15 10528HM 18941HM 1 2 3 2 4 1 2 3 4 15778HM HM46670 17039HM 6 HMI41 HM70 HMD70U Y LiCl 11 RH NaCl 75 RH HUMICAP...

Page 16: ...10 35 11 24 0 20 RL 500 20 35 17 24 0 1 0 5 RH EN 61326 1 1997 1 1998 CISPR16 B EN IEC 61000 4 2 EN IEC 61000 4 4 EN IEC 61000 4 3 GSM ENV50204 1995 A Vaisala Vaisala Oyj Vanha Nurmij rventie 21 FI 0...

Page 17: ...HMD70U Y M210277EN C 18941HM 2 17...

Page 18: ...HMD 0U Y M21027 EN C...

Page 19: ...Spare part sensor part no 15778HM HMD 0U Y M21027 EN C...

Page 20: ...HMD 0U Y M21027 N C INTERCAP 15778HM...

Reviews: