User's Guide ______________________________________________________________________
136 _________________________________________________________________ M211296EN-A
Alarms
The following parameters provide limits for preconfigured alarms:
1012-168
Figure 81
Setting Alarm Limits
Table 35
Alarm Limit Parameters
Monitored Value
Unit
Alarm
Set Name
Limit Type
Default Limit
Air temperature instant
°C
High limit TA_AlarmHigh
high_limit
40
Air temperature instant
°C
Low limit TA_AlarmLow Low_limit
0
Wind speed max 10 min
m/s
High limit WS_Alarm
high_limit
20
Precipitation sum 1 hour
mm
High limit PR_Alarm
high_limit
20
Datalogger temperature
°C
High limit None
Fixed +65 °C 65
Datalogger temperature
°C
Low limit None
Fixed -65 °C
-65
Datalogger supply voltage VDC
Low limit DC_Alarm
Low_limit
10.5