General
Property Description/Value
Heating
Transducer heating 30 W
Operating temperature
-55 ... +70 °C
Operating voltage
Absolute maximum
9 ... 36 VDC
40 VDC
Heating voltage
Typical ranges
Absolute maximum
24 ... 36 VDC
40 VDC
IP class
IP66/IP67
Material
Body
Transducers
Mounting kit
Stainless steel AISI316
Silicone
Stainless steel AISI316
Dimensions (h × w × d)
350 mm h × 250 mm × 285 mm
Weight 2
kg
Connector
Hummel 7.106 series
Dimensions
Figure 134 below and Figure 135 on page 259 show the dimensions of
Ultrasonic Wind Sensor WMT703 and Mounting Kit FIX70.
1001-015
Figure 134
Ultrasonic Wind Sensor WMT703 Dimensions in
Millimeters
Summary of Contents for AWS330