VRT 50 Room Thermostat Operating and Installation Manual

4

VRT 50

-

+

7

8

9

- BUS +

7

8

9

Boiler

L

N

3

4

5

L

N

3

4

5

Fig. 9.1 Electrical connection

10 Start-up

No additional settings are required for the start-up. 
The heating engineer can additionally adapt the (pro-
grammable) room thermostat to the environment or the 
preferences of the user.

10.1 Installer 

level

You can go to the installer level by pressing the dial for 
about 10 seconds.
The spanner symbol   appears on the display.
•  You can switch to the next parameter by pressing the 

dial.

The following parameters can be set:

Parameter 1:

 Setting of a minimum temperature as a 

lower limit for the control range
You can set a minimum temperature by turning the dial.
Setting range 5 … 30° C (default setting: 5° C)

Parameter 2:

 Switchover between two-point and contin-

uous control
You can change the parameter by turning the dial.
 0 = two-point 

control 

(default 

setting)

 1 = continuous 

control

You can exit the installer level as follows:
•  Press the dial for about 5 seconds
or
•  After 5 minutes if you do not operate the dial.
The basic display then reappears. 

10.2 

Handing over the device to the owner

The owner of the (programmable) room thermostat 
must be instructed about its functions and how to oper-
ate it.
•  Hand over the manuals intended for the owner as well 

as the documents of the device.

•  Go through the operating manual with the owner and 

answer any questions.

•  Draw special attention to the safety instructions, 

which the owner must follow.

11 Technical 

data

Description

Unit

Value

Operating voltageU

max

V

24

Maximum permissible ambient temperature

°C

50

Current consumption

mA

17

Minimum cross-section of the connection lines

mm

2

0.75

Level of protection

IP 20

Protection class for controller

III

Dimensions

Height

mm

97

Width

mm

97

Depth

mm

27

Table 11.1 Technical data

12 Vaillant 

service

To ensure regular servicing, it is strongly recommended 
that arrangements are made for a Maintenance Agree-
ment. Please contact Vaillant Service Solutions (0870 
6060 777) for further details.

Summary of Contents for VRT 50

Page 1: ...ease observe the safety instructions in this manual for the installation of the device hNote Useful information and instructions Symbol for a necessary task Safety The programmable room thermostat must be installed by an approved qualified servicing company which is re sponsible for adhering to the existing standards and regulations Operating instructions 1 Overview 1 Key 1 Display 2 Dial turn and...

Page 2: ...nd appropriate instructions in the operating manual of your boiler You can switch on the hot start function by pressing and turning after one second the dial You can switch off the hot start function by pressing and turning after one second the dial again 4 Vaillant warranty See supplement 0020029010 5 Recycling and disposal Neither your programmable room thermostat nor any of its accessories belo...

Page 3: ...ng the snap fit on the bottom 2 flapping the cover of the housing 1 upwards and removing it from the base of the housing 3 4 3 5 6 Fig 8 3 Mounting the programmable room thermostat Drill two holes 5 of 6 mm diameter and insert the supplied wall plugs Lay the connection cable through the duct 6 Attach the housing base 3 to the wall with the two screws provided Connect the connection cable as descri...

Page 4: ...ntinuous control You can exit the installer level as follows Press the dial for about 5 seconds or After 5 minutes if you do not operate the dial The basic display then reappears 10 2 Handing over the device to the owner The owner of the programmable room thermostat must be instructed about its functions and how to oper ate it Hand over the manuals intended for the owner as well as the documents o...

Reviews: