5
Installation instructions VRT 392f 0020044239_01
4 Assembly
The VRT 392f must be installed in the living area against
a wall. The connection with the appliance is made using
a radio link.
4.1
Scope of delivery
Using Table 4.1, check the scope of delivery.
Pos. number
Component
1
1
Room thermostat VRT 392f
2
1
Fixing equipment
3
1
Radio receiver unit
4
1
Wall socket for radio receiver unit
5
1
Battery set (4x AA)
6
1
Operating and Installation instructions
Table 4.1 Scope of delivery VRT 392f
4.2
Accessories
You can use the following add-on accessories with the
VRT 392f:
Multi-functional module VR 40
The VRT 392f can control a circulation pump via the
VR 40 multi-functional module.
h
Note
Observe the manuals for the accessory
components if the VRT 392f is used with
accessories.
4.3
Installation location
Only install the controller and the radio receiver
unit in dry rooms.
The controller should be fitted so as to ensure
problem-free measurement of the room
temperature; e.g. on a room wall of the main living
room at a height of approx. 1.5 m.
Check the mounting locations prior to installing
the controller and radio receiver unit regarding
possible functional impairment of the radio signal
path due to electrical appliances or building
features. If interference in the signal path is likely
an alternative installation location must be found.
Inform the operator that all radiator valves in the
room where the VRT 392f is mounted must be
fully opened.
4.4
Installing the radio receiver unit in the
appliance
e
Danger!
Voltage carrying connections!
When working in the control cabinet of the
appliance there is a danger to life by electric
shock.
Switch the power supply off before working in
the control cabinet and secure against
re-connection.
Open the control cabinet only when the
appliance is potential-free.
This is how to do it:
Switch off the appliance.
Turn off the power supply to the appliance and
secure the power supply to prevent it from being
unintentionally switched back on.
Remove the front panel on the appliance and
remove the cover plate on the control cabinet.
Push the radio receiver unit into the plug
connection provided in the control cabinet using
your plug connector.
Re-connect the power supply to the appliance.
Switch the appliance on.
Check whether the green LED lights up at the
radio receiver unit after a short period of time.
Close the front panel of the appliance.
Assembly 4
Summary of Contents for VRT 392f
Page 2: ......
Page 20: ......
Page 34: ......
Page 35: ......
Page 36: ...0020044239_01 GB 052010 Subject to alterations ...