15
Operating manual VRT 392f 0020044239_01
4.7
Editing screens (examples)
4.7.1
Entering time programmes (example for
heating)
Using the time programmes you can allocate up to three
time windows per weekday, or block of days
(e.g. Mo - Fr). In these time windows, the heating system
maintains the room temperature that you have selected,
the so-called comfort temperature. Outside the time
windows, the room temperature is set back. The
set-back temperature can also be changed.
h
Note
You can save energy without any loss in heating
comfort by finding the best possible match
between the time windows and your lifestyle.
The example below for heating circuit 1 shows
example for the heating circuit. You can define time
windows in a similar way for hot water generation and
for a circulation pump.
Turn the left-hand dial until screen 2
(HC1 time programme) is displayed.
HC 1
Time programme
2
Mo
1
06 : 00 -
10 : 40
21.5 °C
2
:
-
:
3
:
-
:
> Select day of week
Fig. 4.13 Screen 2 (example)
Turn the right-hand dial until the cursor is
positioned in front of the day or block of days
input field.
Click the right-hand dial.
The field is highlighted.
Select the required day or block of days by turning
the right-hand dial. The following options are
available:
– Mo, Tu, ... etc.
– Mo - Fr (Block)
– Sa - Su (Block)
– Mo - Su (Block)
Confirm the selection by clicking with the
right-hand dial.
1, 2 and 3 indicate the "time windows" which you can
programme for the selected weekday or block of days.
The VRT 392f provides heating in accordance with the
corresponding comfort temperature (e.g. 21.5 °C) within
a specific time window (e.g. from 06:00 am to
10:40 am).
Turn the right-hand dial until the cursor is
positioned in front of the input field for the
starting time of time window 1.
Click the right-hand dial.
The field is highlighted.
Set the start time by turning the right-hand dial.
Each step of the dial changes the time by 10 minutes.
Once the desired starting time is displayed,
confirm this by clicking the right-hand dial.
The end time for window 1 should be set similarly.
The comfort temperature for time window 1 is set as
follows:
Turn the right-hand dial until the cursor is
positioned in front of the input field for the
comfort temperature of time window 1.
Click the right-hand dial.
The field is highlighted.
Select the comfort temperature by turning the
right-hand dial (one step corresponds to a change
of 0.5 °C).
Once the desired comfort temperature is
displayed, confirm this by clicking
the right-hand dial.
h
Note
The VRT 392f assists the operator with the
programming of time windows:
The times can only be entered in chronological
order. The time period of a subsequent window
cannot overlap the previous one.
The time window must be between 0:00 and
24:00.
An existing time window can be deleted as
follows: Se the start time and the end time of
a time window to the same time.
Operation 4
Summary of Contents for VRT 392f
Page 2: ......
Page 20: ......
Page 34: ......
Page 35: ......
Page 36: ...0020044239_01 GB 052010 Subject to alterations ...