Operating instructions for electric domestic hot water cylinders VEN 5/6 U and O (plus) 0020129648_02
23
Technical data 15
15 Technical
data
Unit designation
Units
VEN 5/6 U
plus
VEN 5/6 O
plus
Article number
001012791
0010012792
Version
Electric domestic hot water cylinder, open-vented system with mains cable
For supplying
one draw-off point 1)
Design
for undercounter installation
for overcounter installation
Capacity l
5
5
Dimensions 2)
Height 2)
mm
418
418
width mm
240
240
depth mm
218
218
Weight when filled with water
kg
8
8
Performance characteristics
Operating mode
Single-circuit
Single-circuit
Blended water volume from 40 °C 3)
l
9.5
9.5
Standby energy consumption
KWh/24 hrs 0.24
0.24
Max. operating pressure
MPa (bar)
0
0
Configuration
Inner tank
Plastic
Plastic
Temperature can be selected up to
approximately
°C 85
85
Economy mode at approximately
°C
60
60
Temperature limiting possible to 4)
°C
40/60
40/60
Electrical supply
1/N/PE
1/N/PE
Measuring voltage
V/Hz
230/50
230/50
Rated output
kW
2
2
Safety
Radio-shielded, non-interacting with the mains supply
type of protection
IP 24 D= splash-proof
Recommended outlet valve/fitting
Available from unit supplier 5)
Tab. 15.1 Technical data
1) Open-vented system (non-pressurised)
2) Including water connection (without valve/fitting)
3) The blended water volume for a service temperature of 40 °C
results from adding cold water to the 65 °C cylinder water with
the unit ready to operate
4) Water temperature of approximately 40 °C, e.g. for bathroom use;
water temperature of approximately 60 °C, e.g. for kitchen use
5) See price list