Multi Split Type Installation Manual
8
5.10 Technical Specifications
Indoor Units
Units
VA 6-020 MXNHI VA 6-025 MXNHI
VA 6-035 MXNHI VA 10-020 MXNHI VA 10-025 MXNHI
Wall
Capacity
Cooling Capacity
kW
2.00
2.50
3.50
1,94
2.36
Heating Capacity
kW
2.30
2.90
3.80
2.26
2.76
Air Flow
m
3
/h
450/400/370
500/450/400
600/550/500
380/430/480
390/450/520
Sound Power level
dB(A)
56/52/45
56/52/45
56/52/45
30/33/36
31/34/38
Net Dimensions (HxLxD)
mm
285x760x182
285x760x182
285x760x182
265x795x197
265x795x197
Net Weight
kg
8.6
8.6
8.6
7.6
7.6
Panel Net Weight
kg
/
/
/
/
/
Air Drop (static pressure)
Pa
/
/
/
/
/
Pipe Connections
Pipe Connection liq/gas
inches
1/4-3/8
1/4-3/8
1/4-3/8
1/4-3/8
1/4-3/8
Indoor Units
Units
VA 10-035 MXNHI VA 6-035 MXNHKI VA 6-050 MXNHKI VA 6-035 MXNHDI VA 6-050 MXNHDI
Wall
Cassette
Duct
Capacity
Cooling Capacity
kW
3.10
3.24
5.03
3.61
5.15
Heating Capacity
kW
2.80
3.45
5.47
3.85
5.65
Air Flow
m
3
/h
430/480/550
630/530/450
670/600/550
[550/]500/450/400 [1270/]1160/1020/900
Sound Power level
dB(A)
33/36/39
57/53/50
57/53/50
[56/]53/51/48
[59/]57/53/51
Net Dimensions (HxLxD)
mm
265x795x197
260x570x570
260x580x580
220x610x500
220x1090x500
Net Weight
kg
7.6
17
19
14
25
Panel Net Weight
kg
/
2.8
2.8
Air Drop (static pressure)
Pa
/
/
/
20
20
Pipe Connections
Pipe Connection liq/gas
inches
1/4-3/8
1/4-3/8
1/4-1/2 (includes
connector for OU)
1/4-3/8
1/4-1/2 (includes
connector for OU)
Table 5.9 Technical specifications Indoor Unit.
Outdoor Unit
Units
VA 6-060 MXNHO
VA 6-085 MXNHO
VA 6-105 MXNHO
Power Supply
V/Ph/Hz
230/1/50
230/1/50
230/1/50
Cooling Capacity
kW
5.55
8.20
10.27
Power Input
kW
1.72
2.47
3.27
Operating current
A
8,60
12,30
16,30
Performance
Air Flow volume
m
3
/h
3200/2300/1600
4000/3200/2300
4300/3500/2600
Sound Power level
dB(A)
66/63/60
66/63/60
68/65/62
Refrigerant
R410A
Refrigerant charge heat pump
gr
2000
2600
3000
Expansion system
Electronic expansion valve
Dimensions (HxLxD)
mm
680x928x288
840x1068x340
840x1068x340
Net Weight
kg
54
74
75
Pipe Connections
Pipe connection liq/gas
1/4-3/8
1/4-3/8
1/4-3/8
Max. Piping lenght (L1)
m
25
25
25
Max. L1+L2+L3+(L4 fo the 4x1)
m
45
60
60
Max. Height IU under OU
m
10
10
10
Max. Height OU under IU
m
15
15
15
Chargeless length
m
30
40
40
Additional charge per m.
gr
20
20
20
Table 5.10 Technical specifications Outdoor Unit.