14
Installation and maintenance instructions for uniSTOR 0020111105_00
4 Assembly
4.1
Scope of delivery
1
2
3
4
5
6
7
8
Fig. 4.1 Scope of delivery
Item
Quantity Component
1
1
Domestic hot water cylinder with insulation
in separate packaging
2
1
Safety assembly (pressure reducing valve,
expansion relief valve, connections for pres-
sure-controlled cold water inlet and hot water
expansion vessel)
3
1
Two port motorised valve
4
1
Plug for secondary return
5
1
Tundish
6
1
Assembly set for hot water expansion vessel
7
1
Hot water expansion vessel:
12 l for VIH GB 120/2 S and VIH GB 155/2 S
18 l for VIH GB 180/2 S and VIH GB 210/2 S
25 l for VIH GB 260/2 S and VIH GB 310/2 S
8
2
Installation and maintenance instructions
and operating instructions (packaged with
the cylinder)
Table 4.1 Scope of delivery
>
Check the scope of delivery for completeness.
>
Make sure the cylinder is stored in an upright position in
a dry environment prior to its installation.
4.2
Transporting the cylinder
a
Danger!
Risk of injury due to heavy load!
Heavy load can cause injuries.
>
At least two people should lift the cylin-
der to prevent injuries.
>
Use a suitable transportation aid
(sack truck or similar).
>
Transport the packaged cylinder to the installation site.
>
Only remove the cylinder from its packaging once
it reaches the installation site.
4.3 Installation
site
Position the domestic hot water cylinder as near as pos-
sible to the heater to prevent unnecessary heat loss.
Place the cylinder in a suitable location in the building,
paying attention to the following:
– The tundish discharge pipe must be installed with
a minimum downward slope of 1:200 and must end
in a safe and visible place.
– The installation surface must be flat and capable
of bearing the weight of the full cylinder.
– The installation site must not be at risk of frost.
If necessary, install a frost protection thermostat.
– The control system for the installed cylinder thermostat
beneath the front plate must be easily accessible to the
operator.
– There must be sufficient space for mounting, maintai-
ning and replacing the electric immersion heater.
– The floor must be even.
– There must be sufficient space for installing, maintaining
and replacing the expansion vessel.
>
Choose a cylinder installation site that allows the potable
water and heating lines to be laid in an appropriate man-
ner.
>
To prevent energy losses in accordance with current buil-
ding regulations, provide all system pipes with thermal
insulation.
4 Installation