PARTS REPLACEMENT
Automatic bypass
●
Refer to the important information
and initial preparation on page 59.
●
Release central heating water
pressure.
●
Remove spring clip (
2
)
●
Undo union (
1
), remove
bypass/connecting pipe.
●
Pull apart bypass and connecting
pipe.
●
Re-assemble in reverse order.
3
2
1
Fig. E.14: Automatic Bypass
Euro B/S 169/0
☞
picture shows a
TURBOmax Plus
boiler
2
2
1
Fig. E.15: Pressure gauge
Euro B/S171/0
Pressure gauge
●
Refer to the important information
and initial preparation on page 59.
●
Release central heating water
pressure.
●
Pull out the four retaining clips and
remove the pressure gauge from
fascia.
●
Remove retaining clip and
disconnect pressure gauge
capillary tube.
●
Re-assemble in reverse order.
☞
picture shows a TURBOmax Plus boiler