0020334316_02 Operating and installation instructions
9
2.14
Operating and display functions
Note
The functions described in this section are not available for all system configurations.
To call up the menu, press
twice.
2.14.1 Menu item CONTROL
MENU
CONTROL
Zone
Heating
Mode:
Manual
Uninterrupted retention of the desired temperature
Desired temperature: °C
What do the different temperatures mean? (
Time-contr.
What is meant by "time period"? (
Weekly planner
Up to 12 time periods and desired temperatures can be set per
day.
The competent person sets how the heating installation behaves
outside of the time period in the
Set-back mode:
function.
In
Set-back mode:
means:
–
Eco
: The heating is switched off outside of the time periods.
Frost protection is activated.
–
Normal
: The set-back temperature applies outside of the time
periods.
The
Desired temperature: °C
applies within the time periods.
Desired temperature: °C
What do the different temperatures mean? (
Set-back temperature: °C
What do the different temperatures mean? (
Off
Heating is switched off, domestic hot water continues to be avail-
able, frost protection is activated
Cooling
Mode:
Manual
Uninterrupted retention of the desired temperature
Desired temperature: °C
What do the different temperatures mean? (
Time-contr.
What is meant by "time period"? (
Weekly planner
Up to twelve time periods can be set per day
The
Desired temperature: °C
applies within the time periods.
Cooling is switched off outside of the time periods.
Desired temperature: °C
What do the different temperatures mean? (
Off
Cooling is switched off, domestic hot water remains available.
Name of zone
Changing the name
Zone 1
, which was set at the factory
Absence
During this time, heating mode runs at the defined set-back tem-
perature. Domestic hot water mode and circulation are switched
off. Frost protection is activated; existing ventilation runs at the
lowest level.
Factory setting:
Set-back temperature: °C
15 °C
All
Applies for all zones within the specified time period.
Zone
Applies for the selected zone in the specified time period.
Cooling for several days
Cooling mode is activated in the specified time period; cooling
mode and desired temperature are used from the
Cooling
func-
tion
Fixed value control, circuit 1
Mode:
Manual
Uninterrupted retention of the
Target flow temp., desired: °C
that
the competent person set beforehand.
Time-contr.
What is meant by "time period"? (
Summary of Contents for sensoCOMFORT VRC 720/3
Page 2: ...2 en Operating and installation instructions 3 en Country specifics 59...
Page 38: ...38 Operating and installation instructions 0020334316_02 4 9 2 3 Wiring diagram 0020184677...
Page 44: ...44 Operating and installation instructions 0020334316_02 4 9 4 5 Wiring diagram 0020177912...
Page 47: ...0020334316_02 Operating and installation instructions 47 4 9 5 5 Wiring diagram 0020280010...
Page 50: ...50 Operating and installation instructions 0020334316_02 4 9 6 5 Wiring diagram 0020260774...
Page 61: ......
Page 62: ......
Page 63: ......