12
Operating and installation instructions 0020334316_02
Solar yield
Energy yield of the connected solar system
Environmental yield
Energy yield of the heat source installation for the connected heat
pumps
Power consumption
The installation's electrical energy consumption based on the re-
spective system function and/or the overall installation
Heating
Current month
,
Last month
,
Current year
,
Last year
,
Total
DHW
Current month
,
Last month
,
Current year
,
Last year
,
Total
Cooling
Current month
,
Last month
,
Current year
,
Last year
,
Total
Installation
Current month
,
Last month
,
Current year
,
Last year
,
Total
Fuel consumption
The installation's fuel consumption based on the respective system
function and/or the overall installation
Heating
Current month
,
Last month
,
Current year
,
Last year
,
Total
DHW
Current month
,
Last month
,
Current year
,
Last year
,
Total
Installation
Current month
,
Last month
,
Current year
,
Last year
,
Total
Heat recovery
Amount of energy saved by the ventilation unit
Burner status:
Current burner status of the connected boiler
Air quality sensor 1:
Measures the CO
2
content of the room air
Control elements
Explanation of the control elements
Menu introduction
Explanation of the menu structure
Competent person contact info
The competent person can store their telephone number.
Phone number
Company
Serial number
Identification of the product. The 7th to 16th digits of the serial
number form the article number
2.14.3
SETTINGS menu item
MENU
SETTINGS
Installer level
Enter access code
Access to the installer level, factory setting: 00
If the access code is unknown, reset the system control to the fact-
ory setting.
End external Energy Manager
After ending, the system control re-assumes its control function
with its original settings.
Competent person contact info
Entering contact details
Service date:
Enter the next service date for a connected component, e.g. heat
generator, heat pump, ventilation unit
Fault history
Faults are listed in chronological order
Installation configuration
Installation configuration
menu item (
→
section 2.14.4)
Sensor/actuator test
Selecting a connected functional module and
–
carrying out a function check of the actuators.
–
Carry out a plausibility check of the sensors.
Noise reduction mode
Set the time programme in order to reduce the noise level.
Screed drying
Activate the
Screed drying profile
function for freshly laid screed
in accordance with the construction regulations.
The system control regulates the flow temperature independently
of the outdoor temperature.
Set screed drying
Installation configuration
menu item (
→
section 2.14.4)
Change code
Defining an individual access code for the installer level
Language, time, display
Language:
Defining the language that is to be shown on the display.
Date:
After the power is switched off, the date is retained for approx. 30
minutes.
Summary of Contents for sensoCOMFORT VRC 720/3
Page 2: ...2 en Operating and installation instructions 3 en Country specifics 59...
Page 38: ...38 Operating and installation instructions 0020334316_02 4 9 2 3 Wiring diagram 0020184677...
Page 44: ...44 Operating and installation instructions 0020334316_02 4 9 4 5 Wiring diagram 0020177912...
Page 47: ...0020334316_02 Operating and installation instructions 47 4 9 5 5 Wiring diagram 0020280010...
Page 50: ...50 Operating and installation instructions 0020334316_02 4 9 6 5 Wiring diagram 0020260774...
Page 61: ......
Page 62: ......
Page 63: ......