background image

Notes on the documentation 2

0020159950_07 recoVAIR Operating instructions

5

2

Notes on the documentation

2.1

Observing other applicable documents

You must observe all operating instructions enclosed with
the system components.

2.2

Storing documents

Keep this manual and all other applicable documents
safe for future use.

2.3

Validity of the instructions

These instructions apply only to:

Product article number

Applicability:

Switzerland

Switzerland

VAR 260/4

0010016042

VAR 260/4 E

0010016350

VAR 360/4

0010016041

VAR 360/4 E

0010016351

Product article number

Applicability:

Germany

Germany

VAR 260/4

0010016040

VAR 260/4 E

0010016348

VAR 360/4

0010015166

VAR 360/4 E

0010016349

Product article number

Applicability:

Austria

Austria

VAR 260/4

0010016040

VAR 260/4 E

0010016348

VAR 360/4

0010015166

VAR 360/4 E

0010016349

3

Product description

This product is a domestic ventilation unit.

3.1

Role and function

Task

The product aerates and ventilates living spaces and en-
sures a constant exchange of air with heat recovery in the
building.

Furthermore, the product guarantees the hygienically ne-
cessary minimum air exchange and prevents damage to the
building caused by moisture and mould.

Functionality

1

2

3

4

5

The product

(5)

is the central component in controlled room

ventilation. Fresh outside air

(4)

is guided to the living rooms

and bedrooms via air intake openings

(2)

. The used air from

the kitchen, bathroom and WC is guided outside

(1)

via the

exhaust air openings

(3)

.

4

3

2

1

The exhaust air

(2)

from the dwelling is guided to the

product. The filter for the exhaust air cleans the exhaust
air and guides the exhaust air to the heat exchanger. The
heat exchanger extracts the heat from the exhaust air (heat
recovery). The cooled air is guided outside as exit air

(4)

.

The outside air

(1)

is guided to the product from the outside.

The filter for the outside air cleans the outside air and guides
the outside air to the heat exchanger. The heat exchanger
transfers the heat from the exhaust air to the outside air. The
heated air is guided to the dwelling as supply air

(3)

.

On summer nights, the outside temperature is often lower
than the room temperature. Through the automatic bypass,
the cooler outside air is no longer preheated by the heat ex-
changer. The bypass guides the warmer exhaust air past the
heat exchanger directly outside. The frost protection function
reduces the supply air volume flow according to demand,
which leads to an increase in the exit air temperature. This
prevents the heat exchanger from freezing. If the reduction in
the supply air volume flow is no longer sufficient, the product
switches off.

The humidity sensor records the current moisture in the
exhaust air. If you operate the product in auto mode, the
current air volume flow is regulated according to demand
(

aguaCARE

.

Summary of Contents for recoVAIR VAR 260/4 E

Page 1: ...ing instructions recoVAIR VAR 260 4 E VAR 360 4 E AT CH de DE Publisher manufacturer Vaillant GmbH Berghauser Str 40 D 42859 Remscheid Tel 49 21 91 18 0 Fax 49 21 91 18 2810 info vaillant de www vaill...

Page 2: ...Basic display 7 4 3 Operating levels 7 4 4 Operator level overview 8 4 5 Switching the product on off 8 4 6 Setting the ventilation 8 4 7 Setting the desired temperature 9 5 Troubleshooting 9 5 1 Det...

Page 3: ...duct can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabil ities or lack of experience and knowledge if they have been given supervision or in...

Page 4: ...seals on components Only qualified competent persons and customer service personnel are authorised to make modifications to sealed components Do not make any changes The product itself to the product...

Page 5: ...ide air 4 is guided to the living rooms and bedrooms via air intake openings 2 The used air from the kitchen bathroom and WC is guided outside 1 via the exhaust air openings 3 4 3 2 1 The exhaust air...

Page 6: ...ion of the right hand selection button 3 Left and right hand selection buttons 4 button button 5 Access to the menu for additional information 6 Display of the current configuration of the left hand s...

Page 7: ...he change to a setting and the reading of a value or to exit the selection level by pressing the left hand selection button If you do not press any buttons for more than 15 minutes the display returns...

Page 8: ...should have your product serviced 4 4 8 Maintenance interval overdue Menu Information Maintenance overdue You can use this function to read by how long the mainten ance for your product is overdue 4 4...

Page 9: ...c display Use and to select the desired temperature Adjustment range 16 28 Confirm by pressing 5 Troubleshooting 5 1 Detecting and rectifying faults Danger Risk of death from electric shock Risk of de...

Page 10: ...tdoor air filter 1 and the exhaust air filter 2 out of the product 4 Check the filters for dirt Recommended check Every three months 1 2 Degree of contamination Filter is lightly soiled Caution Risk o...

Page 11: ...hon while taking into consideration the drip distance 1 Drip distance 20 mm 4 Fill the condensate siphon dry siphon with water 6 2 5 Establish system efficiency 1 Clean the supply and exhaust air valv...

Page 12: ...ge Kosten die Ihnen bei der Durchf hrung von Arbeiten an dem Ger t w hrend der Garantiezeit entstehen nur dann erstatten falls wir Ihnen einen entsprechenden Auftrag erteilt haben und es sich um einen...

Page 13: ...recovery Current value Power efficiency Current value Wh m 3 Exhaust air temp Current value Exhaust air humidity Current value rel Supply air temp Current value Outside air temp Current value Supply...

Page 14: ...ooms are passively cooled S 804 Heat recovery 50 The bypass is half open The rooms are also passively cooled However part of the volume flow is guided through the heat exchanger in order to prevent su...

Page 15: ...atically switches on no later than 60 minutes after the temperature increases Outside temperature 3 Product has a reduced air flow Filter slightly dirty Clean the filters Filter heavily dirty Replace...

Page 16: ...n aus dem Mobilfunknetz ggf abweichende Tarife n here Information erhalten Sie bei Ihrem Mobilnetzbetreiber info vaillant at termin vaillant at www vaillant at www vaillant at werkskundendienst Vailla...

Reviews: