31
Operating Manual geoTHERM VWS/VWW 0020051547_02
GB
7.3 Data
badge
R407
C
COP
B0/W35
4,3
COP
B5/W55
2,9
B0/W35
B5/W55
3/N/PE 400V 50Hz
IP 20
Vaillant GmbH Remscheid / Germany
1/N/PE 230V 50Hz
3/N/PE 400V 50Hz
9,1 kW
3,1 kW
6 kW
26 A
<16 A
1,9 kg
2,9 (29)
MPa (bar)
5,9 kW
6,4 kW
VWS 61/2
DE AT CH
Serial-No. 21054500100028300006000001N1
21054500100028300006000001N4
16 A
-- I
-- MPa
(bar)
Fig. 7.1 Example of an identification plate
Explanation of the symbols on the identification plate
Rated voltage - compressor
Rated voltage pumps + controller
Rated voltage - auxiliary heating
Rated maximum power
Rated power for compressor,
pumps and controller
Rated power for auxiliary heating
Start-up current without start-up
current limiter
16 A
Start-up current with start-up cur-
rent limiter
Service water tank capacity
Permissible rated overpressure
Coolant type
Filling quantity
Permissible rated overpressure
COP
B0/W35
Performance figure at a brine tem-
perature of 0 °C and a heating flow
temperature of 35 °C
COP
B5/W55
Performance figure at a brine tem-
perature of 5 °C and a heating flow
temperature of 55 °C
B0/W35
Thermal output with a brine tem-
perature of 0 °C and a heating flow
temperature of 35 °C
B5/W55
Thermal output with a brine tem-
perature of 5 °C and a heating flow
temperature of 55 °C
CE mark
VDE/GS mark
Read the Operating and Installation
Manual!
Humidity protection class
Ensure proper disposal at the end
of its working life (not household
waste)
21054500100028300006000001N4
Serial Number
Table 7.3 Explanation of symbols
Appendix 7