Appendix
0020213395_00 flexoTHERM exclusive Installation and maintenance instructions
41
Setting level
Values
Unit
Increment, select, ex-
planation
Default setting
Setting
Min.
Max.
Freeze protection
Ground/brine:
−
14
Well: +2
5
℃
1
Ground/brine: -7
Well: +2
Heat. rod outp. range
External
9
kW
1
230 V
–
External
–
2 kW
–
3.5 kW
–
5.5 kW
–
7 kW
–
9 kW
5.5
Cooling technology
No cool-
ing
On-site
pass.
cooling
No cooling
Active cooling
On-site pass. cooling
On-site pass. cooling
No cooling
Check program: Purge environ-
ment and building circuit
Test not
active
Test act-
ive
Test not active, Test
active
Test not active
Check program: Purge building
circuit
Test not
active
Test act-
ive
Test not active, Test
active
Test not active
Check program: Purge environ-
ment circuit
Test not
active
Test act-
ive
Test not active, Test
active
Test not active
Contact details, Telephone num-
ber
Phone number
0 - 9
Empty
End the installation assistant?
Yes, back
1)
See overview of fault codes
D
Status codes
–
Overview
Status code
Meaning
Displays relating to the heat pump system
S.34
Heating mode: Frost protection
S.91
Service message: Demo mode
S.100
Standby
S.101
Heating: Compressor switched off
S.102
Heating: Compressor blocked
S.103
Heating: Flow
S.104
Heating: Compressor active
S.107
Heating: Overrun
S.111
Cooling: Compressor shutdown
S.112
Cooling: Compressor blocked
S.113
Cooling: Compressor mode flow
S.114
Cooling: Compressor active
S.117
Cooling: Compressor mode overrun
S.118
Cooling: Flow
S.119
Cooling: Mixer active
S.125
Heating: Heating rod active
S.131
Hot water: Compressor shutdown
S.132
Hot water: Compressor blocked
S.133
Hot water: Flow
S.134
Hot water: Compressor active
S.135
Hot water: Heating rod active
S.137
Hot water: Overrun