4 Set-up
6
Installation and maintenance instructions eloSTOR exclusive 0020234040_02
4.2
Requirements for the installation site
▶
Observe the following requirements:
–
Installation only in rooms that are always dry and free
of frost
–
Installation only on a level, vertical and stable wall
–
Installation only on a wall with sufficient load-bearing
capacity for the filled product (
→
Appendix: Technical
data)
Conditions
: Non-pressurised installation
–
Installation height above sea level: < 2000 m
4.3
Observing the minimum clearances
≥500
▶
Comply with the minimum clearances during installation.
4.4
Installing the product
A1
A2
220 - 305
240
100
R ½
R ½
350
100
R1
6
1
2
3
5
4
1
Product bracket (re-
placement for VEH /5)
2
Product bracket (new
installation or replace-
ment for VEH /6 or /7)
3
Bearing surfaces for
wall support
4
Hot water connection
5
Discharge connection
6
Cold water connection
A1
Distance between the
product bracket and
water connections (re-
placement for VEH /5)
A2
Distance between the
product bracket and
water connections
(new installation or
replacement for VEH /6)
1.
Install the product bracket.
[mm]
A1
A2
VEH 50
790
690
VEH 80/100/120
1020
920
2.
Hang the product in the product bracket.
–
Lateral corrections are possible as a result of move-
ment.
Conditions
: Pressure-tight installation of a VEH 50, VEH 100 or VEH 120
▶
Install a suitable safety group on the VEH's water con-
nections.
Conditions
: Pressure-tight installation of a VEH 80
▶
Install a suitable safety group on the VEH's water con-
nections.
▶
Replace the connectors from the safety group with the
connectors supplied for the VEH 80:
–
Vaillant connection pipe 0020192421
–
Vaillant connection pipe 0020192422