Notes on the documentation 2

0020239016_01 ecoTEC plus Operating instructions

7

2 Notes on the

documentation

2.1 Observing other applicable

documents

You must observe all operating instruc-
tions enclosed with the system compon-
ents.

2.2 Storing documents

Keep this manual and all other applic-
able documents safe for future use.

2.3 Applicability of the

instructions

These instructions apply only to:

Product article number

Article
number

Gas Coun-
cil Number

VU 246/6-5 OVZ
(P-GB)

0010021225 41-694-18

3 Product description

3.1 Serial number

The serial number is located on a plate be-
hind the front flap. The plate is in a plastic
fish plate. You can also display the serial
number in the display.

3.2 Information on the

identification plate

The identification plate is mounted on the
underside of the product in the factory.
The identification plate keeps record of
the country in which the product is to be
installed.

Information
on the identi-
fication plate

Meaning

Barcode with serial number

Information
on the identi-
fication plate

Meaning

Serial number

For quality control purposes;
3rd and 4th digits = year of
production
For quality control purposes;
5th and 6th digits = week of
production
For identification purposes;
7th to 16th digits = product
article number
For quality control purposes;
17th to 20th digits = place of
manufacture

ecoTEC plus

Product designation

3P, G31

3.7 kPa

(37 mbar)

Factory setting for type of
gas and gas connection
pressure

Cat.

Gas-fired boiler category

Condensing
technology

Efficiency class of the boiler
in accordance with EC Dir-
ective 92/42/EEC

Type: Xx3(x)

Permissible flue gas connec-
tions

PMS

Maximum water pressure in
heating mode

PMW

Maximum water pressure in
hot water handling mode

V/Hz

Electrical connection

W

Max. electrical power con-
sumption

IP

Level of protection
Heating mode

P

n

Nominal heat output range
in heating mode

P

nc

Nominal heat output range
in heating mode (condensing
technology)

P

Nominal heat output range
in hot water handling mode

Q

n

Nominal heating load range
in heating mode

Q

nw

Nominal heating load range
in hot water handling mode

T

max.

Max. flow temperature

NOx

NOx class for the product

Code (DSN)

Specific product code

Summary of Contents for ecoTEC VU 246/6-5 OVZ

Page 1: ...ing instructions ecoTEC plus VU 246 6 5 OVZ P GB GB IE Operating instructions Publisher manufacturer Vaillant GmbH Berghauser Str 40 D 42859 Remscheid Tel 49 21 91 18 0 Fax 49 21 91 18 2810 info vaill...

Page 2: ...2 Opening and closing the front flap 11 4 3 Switching on the product 11 4 4 Setting the language 11 4 5 Setting the hot water temperature 11 4 6 Setting the heating flow temperature 11 4 7 Switching o...

Page 3: ...al heating installations and for hot water generation Intended use includes the fol lowing observance of the operating instructions included for the product and any other system components compliance...

Page 4: ...Avoid rooms that smell of gas If possible open doors and windows fully and ensure adequate ventilation Do not use naked flames e g lighters matches Do not smoke Do not use any electrical switches mai...

Page 5: ...not make any changes The product itself to the gas air water and electricity supplies to the entire flue gas install ation to the entire condensate drain system to the expansion relief valve to the d...

Page 6: ...t all rooms are sufficiently heated If you cannot ensure the op eration have a competent person drain the heating in stallation 1 3 11 Risk of injury and material damage due to maintenance and repairs...

Page 7: ...mber Information on the identi fication plate Meaning Serial number For quality control purposes 3rd and 4th digits year of production For quality control purposes 5th and 6th digits week of productio...

Page 8: ...pleted the Benchmark Checklist on the inside back pages of the installation instructions supplied with the product and that you have signed it to say that you have received a full and clear ex planati...

Page 9: ...t burner modulation rate Sym bol Meaning Explanation Heating mode active Permanently on Heating mode heat requirement Flashing Burner on in heating mode Maintenance re quired Information on the mainte...

Page 10: ...switch back to the basic display by Pressing to exit the selection levels Not pressing any button for longer than 15 minutes If there is an error message present the basic displays switches to the err...

Page 11: ...st Le gionella Set the hot water temperature to a maximum of 50 C 45 DHW temperature Back 1 Press The set hot water temperature flashes in the display Conditions No controller connected Change the hot...

Page 12: ...and that all rooms are sufficiently heated even when you are away Note To keep the frost protection devices active you should switch your product on and off using the controller if one is provided If...

Page 13: ...mpetent person 7 4 Reading maintenance messages If the symbol is shown in the display the product requires maintenance work The product is not in fault mode but continues to operate Consult a competen...

Page 14: ...approved at the time by the Health and Safety Executive one year after install ation The cost of this annual service is not included in the guarantee Registering with us Registration is simple Just co...

Page 15: ...ng is dis connected Check the fuse in the building The product switches on automat ically when the power is restored The product is switched off Switch on the product The heating flow temperature is s...

Page 16: ...Operating instructions ecoTEC plus 0020239016_01 Fault Cause Measure Heating does not start The external controller is not set cor rectly Set the external controller cor rectly Controller operating in...