Installation and maintenance instructions ecoTEC pure 0020258016_01
Dia-
gnostics
code
Parameter
Values
Unit
Increment, select, explanation
Default set-
ting
Own setting
Min.
Max.
d.67
Remaining burner anti-
cycling time (setting un-
der d.02)
Current value
min
–
–
Not
adjustable
d.68
Number of unsuccessful
ignitions at 1st attempt
Current value
–
–
–
Not
adjustable
d.69
Number of unsuccessful
ignitions at 2nd attempt
Current value
–
–
–
Not
adjustable
d.71
Maximum heating flow
set target temperature
30
80
℃
1
→
Section
"Technical
data"
Adjustable
d.73
Correction of the hot wa-
ter warm start temperat-
ure
-15
5
K
Applies to: Combi boiler
1
0
Adjustable
d.75
Maximum cylinder re-
heating time
20
90
min
Applies to: Product with heating
mode only
1
45
Adjustable
d.77
Max. cylinder reheating
–
–
kW
Applies to: Product with heating
mode only
1
→
Section "Technical data"
–
Adjustable
d.80
Running time in heating
mode
Current value
h
Running time = Display value x
100
–
Not
adjustable
d.81
Running time in hot wa-
ter handling mode
Current value
h
Running time = Display value x
100
–
Not
adjustable
d.82
Number of burner igni-
tions in heating mode
Current value
–
Number of ignitions = Display
value x 100
–
Not
adjustable
d.83
Number of burner igni-
tions in hot water hand-
ling mode
Current value
–
Number of ignitions = Display
value x 100
–
Not
adjustable
d.84
Maintenance in
0
3000
h
Number of hours = Display value
x 10
_ _ _
Not
adjustable
d.85
Increase in the min. out-
put (heating and hot wa-
ter handling mode)
–
–
kW
1
–
Adjustable
d.88
Flow rate limit value
for ignition in hot water
handling mode
0
1
–
Applies to: Combi boiler
0 = 1.5 l/min (no delay)
1 = 3.7 l/min (2 s delay)
0
Adjustable
d.90
Status of the eBUS room
thermostat
Current value
–
off = Not connected
on = Connected
–
Not
adjustable
d.91
Status DCF77
Current value
–
–
–
Not
adjustable
d.93
Setting the product code
0
99
–
1
The Device Specific Number
(DSN) can be found on the iden-
tification plate.
–
Adjustable
d.94
Delete fault list
0
1
–
0 = No
1 = Yes
–
Adjustable
d.95
Software versions
–
–
–
1 = Main PCB
2 = Interface PCB
–
Not
adjustable
d.96
Default setting (reset)
0
1
–
0 = No
1 = Yes
–
Adjustable