Appendix
34
Installation and maintenance instructions ecoTEC pure 0020258016_01
Dia-
gnostics
code
Parameter
Values
Unit
Increment, select, explanation
Default set-
ting
Own setting
Min.
Max.
d.07
Set target temperature
for the domestic hot wa-
ter cylinder
Current value
℃
Applies to: Product with heat-
ing mode only, connected to do-
mestic hot water cylinder with
temperature sensor
–
Not
adjustable
d.09
Heating flow set target
temperature that is set
on the eBUS room ther-
mostat
Current value
℃
–
–
Not
adjustable
d.10
Status of the internal
pump in the heating cir-
cuit
Current value
–
off / on
–
Not
adjustable
d.11
Status of the heating
circuit's shunt pump
Current value
–
Applies to: Installed heating cir-
cuit shunt pump (optional)
off / on
–
Not
adjustable
d.13
Status of the hot water
circuit's circulation pump
Current value
–
Applies to: Installed hot water
circuit circulation pump (optional)
off / on
–
Not
adjustable
d.14
Operating mode of the
modulating pump
0
5
–
0 = Speed-regulated (automatic
pump operation in levels 1 to 5)
1 = PWM = 65 %
2 = PWM = 73 %
3 = PWM = 80 %
4 = PWM = 88 %
5 = PWM = (95 … 100 %)
1; 2; 3; 4; 5 = Fixed rotational
speeds
→
Section "Setting the
pump output"
0
Adjustable
d.15
Pump speed
Current value
%
–
–
Not
adjustable
d.16
Status of the 24 V room
thermostat (ON/OFF)
Current value
–
off = Heating off
on = Heating activated or eBUS
controller used
–
Not
adjustable
d.17
Heating control
–
–
–
off = Flow temperature
on = Return temperature (ad-
justment for underfloor heating.
If you have activated the return
temperature control, the auto-
matic heating output determina-
tion function is not active.)
0
Adjustable
d.18
Pump overrun operating
mode
1
3
–
1 = Comfort (continuously operat-
ing pump)
3 = Eco (pump runs intermit-
tently)
3
Adjustable
d.20
Maximum hot water set
target temperature
50
60
℃
1
60
Adjustable
d.21
Status of the warm start
for hot water
Current value
–
off = Function deactivated
on = Function activated and
available
–
Not
adjustable
d.22
Status of the hot water
request
Current value
–
off = No current requirement
on = Current requirement
–
Not
adjustable
d.23
Status of the heating
demand
Current value
–
off = Heating off (Summer mode)
on = Heating on
–
Not
adjustable
d.25
Status of the requirement
to reheat the cylinder or
for the hot water warm
start from the eBUS ther-
mostat
Current value
–
off = Function deactivated
on = Function activated
–
Not
adjustable