0020308121_04 Installation and maintenance instructions
83
Code/meaning
Possible cause
Measure
F.326
The hydraulic sensor and actu-
ator test has detected at least
two hydraulic components that
are not working.
3-port diverter valve defective or
blocked
▶
Check and, if required, replace the 3-port diverter valve.
Plug on 3-port motorised valve
loose/not plugged in
▶
Check the plug and the plug connection on the 3-port motor-
ised valve.
Interruption in the wiring har-
ness
▶
Check the wiring harness including all plug connections and, if
required, replace it.
Domestic hot water circuit not
connected
▶
Connect the domestic hot water circuit.
External pump runs continu-
ously
▶
Check the external pump and the system configuration.
The pump is defective.
▶
Check and, if required, replace the pump.
F.327
The minimum heating volume
flow is limited due to there be-
ing no domestic hot water cir-
cuit connected.
Cylinder bypass not connected
▶
Check the cylinder connection pipes.
Domestic hot water circuit
clogged/blocked
▶
Check the secondary heat exchanger for dirt.
F.330
The pump is not responding to
commands during the hydraulic
test.
Fault in the electrical connection
for the pump
▶
Check the wiring harness between the PCB and pump, includ-
ing all plug connections.
The pump is defective.
▶
Check and, if required, replace the pump.
F.334
The configuration of the flue
system was not completed.
Flue system configuration not
completed
▶
Check the flue gas configuration and complete this.
F.336
The unit is not permitted in this
configuration.
Flue system configuration set
incorrectly
▶
Set the approved flue system configuration.
Incorrect gas type set
▶
Check the gas type and the gas type setting under
D.156
and
D.157
.
F.337
The multiple-flue configuration
conversion set is not suitable
for the heat cell.
The multiple-flue configuration
conversion set is not suitable
for the heat cell
▶
Check and, if required, replace the conversion set comprising
air intake pipe with integrated non-return valve and air-mass
flow sensor.
F.338
Incorrect multiple-flue configura-
tion setting
Multiple-flue configuration set
incorrectly
▶
Set the approved flue system configuration.
F.342
The air-mass flow is not within
the permitted limits.
Fan speed does not correspond
to the target value
▶
Use
D.033
and
D.034
to check whether the fan speed deviates
by more than 20
–
30 rpm.
Plug on PCB loose/not plugged
in
▶
Check the plug and the plug connection.
Interruption in the wiring har-
ness
▶
Check the wiring harness including all plug connections and, if
required, replace it.
Plug for air-mass flow sensor
loose/not plugged in
▶
Check the plug and the plug connection for the air-mass flow
sensor.
You exit the measuring range
permanently. Air-mass flow
sensor defective
▶
Replace the entire air intake pipe.
Flue gas pipe blocked
▶
Check the entire flue gas pipe.
F.343
The signal for the air-mass flow
sensor is not plausible.
Plug for air-mass flow sensor
loose/not plugged in
▶
Check the plug and the plug connection for the air-mass flow
sensor.
Plug on PCB loose/not plugged
in
▶
Check the plug and the plug connection.
Interruption in the wiring har-
ness
▶
Check the wiring harness including all plug connections and, if
required, replace it.
Measurement discrepancy too
high. Air-mass flow sensor dirty.
▶
Check the air-mass flow sensor for dirt.
You exit the measuring range
permanently. Air-mass flow
sensor defective
▶
Replace the entire air intake pipe.
PCB defective
▶
Replace the PCB.
F.344
The control electrode can no
longer be used.
Transmission fault for calibra-
tion values
▶
Replace the control electrode (
D.146
,
D.147
).