12
Installation and maintenance instructions 0020308121_04
5.10
Design of the product's hydraulic block
2
4
5
7
6
9
8
1
10
3
1
Secondary heat ex-
changer
2
Plug
Hydraulic block without
impeller water flow
sensor (-> Design of
the shift-load cylinder)
3
Strainer at the cold
water inlet
Hydraulic block without
flow rate limiter
4
Prioritising diverter
valve
5
Purging hose
6
Condensate siphon
7
Manometer
8
High-efficiency pump
9
Expansion relief valve
10
Connectivity Interface
Module
5.11
Design of the product's shift-load cylinder
6
4
3
7
8
5
2
1
1
Cylinder charging pump
2
Impeller sensor
3
Temperature sensor at
the domestic hot water
cylinder's outlet
4
Temperature sensor at
the domestic hot water
cylinder's inlet
5
Expansion relief valve
6
Temperature sensor for
the domestic hot water
cylinder
7
Expansion vessel
8
Shift-load cylinder PCB
5.12
Safety Devices
5.12.1 Electrical Supply Failure
The boiler will not work without an electrical supply. Normal
operation of the boiler should resume when the electrical
supply is restored.
Reset any external controls, to resume normal operation of
the central heating.
If the boiler does not resume normal operation press the
reset button. If the boiler does not resume normal operation
after this call your Installation/Servicing company or Vaillant
service.
5.12.2 Overheating Safety
The boiler software is designed to recognise the potential for
an overheat lockout and will shutdown before this happens.
To restart the boiler, press the reset button on the boiler
interface.
If the boiler fails to resume normal operation and all external
controls are calling for heat, then call your Installation/ Servi-
cing company or Vaillant service.
5.12.3 Frost protection
The appliance has a built in frost protection device that pro-
tects the boiler from freezing. With the gas and electric sup-
plies ON and irrespective of any room thermostat setting, the
frost protection device will operate the pump when the tem-
perature of the boiler water falls below 12 °C.
A timer is used so that the temperature can be checked peri-
odically. After 10 minutes the pump will be stopped if the
temperature is higher than 15 °C or has already reached
35 °C. The burner will activate if the boiler temperature does
not reach 15 °C after 30 minutes or at any time if the temper-
ature drops to 5 °C.
The burner will switch off when the temperature reaches
35 °C.
5.12.4 Condensate Drain Blockage
As a safety feature the boiler will stop working if the con-
densate drain becomes blocked. During freezing conditions
this may be due to the forming of ice in the condense drain
external to the house. Release an ice blockage by the use
of warm cloths on the pipe. After pressing reset the boiler
should restart.
6
Set-up
6.1
Checking the scope of delivery
▶
Check that the scope of delivery is complete and intact.
Quantity
Designation
1
Condensing boiler
1
Shift-load cylinder
1
Wall installation set:
1
- Unit mounting bracket
1
- Bag with small parts
1
Shift-load cylinder installation set containing
the following:
2
- Connection pipe (heating flow and return)
1
- Shift-load cylinder-in connection pipe