background image

Care and maintenance 7

0020239012_02

 

ecoTEC

 

plus

 

Operating

 

instructions

13

7

 

Care

 

and

 

maintenance

7.1

 

Maintenance

An

 

annual

 

inspection

 

of

 

the

 

product

 

carried

 

out

 

by

 

a

 

competent

 

person

 

is

 

a

 

prerequis-

ite

 

for

 

ensuring

 

that

 

the

 

product

 

is

 

perman-

ently

 

ready

 

and

 

safe

 

for

 

operation,

 

reliable,

 

and

 

has

 

a

 

long

 

working

 

life

After servicing, complete the relevant 

service interval record section of the 

benchmark checklist, located at the rear of 

the installation manual

.

7.2

 

Caring

 

for

 

the

 

product

Caution.
Risk of material damage
caused by unsuitable clean-
ing agents.

Do not use sprays, scouring
agents, detergents, solvents
or cleaning agents that con-
tain chlorine.

Clean the casing with a damp cloth and
a little solvent-free soap.

7.3 Checking the condensate

drain pipework and tundish

The condensate drain pipework and tun-
dish must always be penetrable.

Regularly check the condensate drain
pipework and tundish for faults and,
particularly, for blockages.

You must not be able to see or feel any
obstructions in the condensate drain pipe-
work and tundish.

If you notice a fault, have it rectified by
a competent person.

7.4 Reading maintenance

messages

If the

symbol is shown in the display, the

product requires maintenance work. The
product is not in fault mode but continues
to operate.

Consult a competent person.

8 Decommissioning

8.1 Temporarily decommissioning

the product

Switch off the product via the main
switch installed on-site.

The display goes out.

When decommissioning the product for
an extended period (e.g. holiday), also
close the gas isolator cock.

8.2 Permanently

decommissioning the product

Have a competent person permanently
decommission the product.

9 Recycling and disposal

The competent person who installed
your product is responsible for the dis-
posal of the packaging.

If the product is identified with this

symbol:

In this case, do not dispose of the
product with the household waste.

Instead, hand in the product to a collec-
tion centre for old electrical or electronic
appliances.

Caution.
Risk of material damage due
to frost.

The frost protection and mon-
itoring devices are only active
while the unit is connected to
the power mains and the gas
isolator cock is open.

Temporarily decommission
the product only if no frost is
expected.

Summary of Contents for ecoTEC plus VU 6/6-5 OVZ Series

Page 1: ...ting instructions ecoTEC plus VU 6 6 5 OVZ H GB GB IE Operating instructions Publisher manufacturer Vaillant GmbH Berghauser Str 40 D 42859 Remscheid Tel 49 21 91 18 0 Fax 49 21 91 18 2810 info vailla...

Page 2: ...2 Opening and closing the front flap 11 4 3 Switching on the product 11 4 4 Setting the language 11 4 5 Setting the hot water temperature 11 4 6 Setting the heating flow temperature 11 4 7 Switching o...

Page 3: ...al heating installations and for hot water generation Intended use includes the fol lowing observance of the operating instructions included for the product and any other system components compliance...

Page 4: ...rooms that smell of gas If possible open doors and windows fully and ensure adequate ventilation Do not use naked flames e g lighters matches Do not smoke Do not use any electrical switches mains plug...

Page 5: ...not make any changes The product itself to the gas air water and electricity supplies to the entire flue gas install ation to the entire condensate drain system to the expansion relief valve to the d...

Page 6: ...t all rooms are sufficiently heated If you cannot ensure the op eration have a competent person drain the heating in stallation 1 3 11 Risk of injury and material damage due to maintenance and repairs...

Page 7: ...formation on the identification plate The identification plate is mounted on the underside of the product in the factory The identification plate keeps record of the country in which the product is to...

Page 8: ...ties on both manufacturers and installers The purpose is to ensure that customers are provided with the correct equipment for their needs that it is installed commissioned and serviced in accordance w...

Page 9: ...t burner modulation rate Sym bol Meaning Explanation Heating mode active Permanently on Heating mode heat requirement Flashing Burner on in heating mode Maintenance re quired Information on the mainte...

Page 10: ...switch back to the basic display by Pressing to exit the selection levels Not pressing any button for longer than 15 minutes If there is an error message present the basic displays switches to the err...

Page 11: ...st Le gionella Set the hot water temperature to a maximum of 50 C 45 DHW temperature Back 1 Press The set hot water temperature flashes in the display Conditions No controller connected Change the hot...

Page 12: ...and that all rooms are sufficiently heated even when you are away Note To keep the frost protection devices active you should switch your product on and off using the controller if one is provided If...

Page 13: ...in pipe work and tundish If you notice a fault have it rectified by a competent person 7 4 Reading maintenance messages If the symbol is shown in the display the product requires maintenance work The...

Page 14: ...approved at the time by the Health and Safety Executive one year after install ation The cost of this annual service is not included in the guarantee Registering with us Registration is simple Just co...

Page 15: ...ng is dis connected Check the fuse in the building The product switches on automat ically when the power is restored The product is switched off Switch on the product The heating flow temperature is s...

Page 16: ...Operating instructions ecoTEC plus 0020239012_02 Fault Cause Measure Heating does not start The external controller is not set cor rectly Set the external controller cor rectly Controller operating in...