4 Operation

10

Operating

 

instructions

 

ecoTEC

 

plus

 

0020239012_02

Op-
erator
control
element

Meaning

+

at the
same
time

Displaying the current product
status

or

Reducing or increasing the set
value

The selection buttons have a soft key func-
tion, i.e. their function can change.
If, for example, you press the left-hand
selection button

in the basic display,

the current function switches from

(hot

water temperature) to

Back

.

Adjustable values flash in the display.
You must always confirm a change to a
value. Only then is the new setting saved.
The display lights up when you switch the
product on or press a button.
If you do not press any button within one
minute, the display lighting goes out.

3.8 Basic display

50

The basic display shows the current condi-
tion of the product. If you press a selection
button, the activated function is displayed
in the display.
The functions that are available depend
on whether a controller is connected to the
product.
You can switch back to the basic display
by:

Pressing

to exit the selection levels

Not pressing any button for longer than
15 minutes.

If there is an error message present, the
basic displays switches to the error mes-
sage.

3.9 Operating levels

The product has two operating levels.

The end user level contains information
and setting options that you require as
the end user.

The installer level is reserved for the
competent person. It is protected by
a code. Only competent persons may
change any settings in the installer
level.

3.10 Menu display

Menu

Live monitor

Information

Reset anti-cycl. time

Back

Select

1

4

3

2

1

Scroll bar

2

Current assign-
ment of the
and

buttons.

3

Selection level
list entries

4

Name of the se-
lection level

You can find an overview of the menu
structure in the appendix.
Operator level

overview (

Page 15)

4 Operation

4.1 Opening the isolator devices

1. Ask the competent person who in-

stalled the product to explain to you
where these isolator devices are loc-
ated and how to handle them.

2. Open the gas isolator cock fully.
3. Check that the heating installation flow

and return service valves are open, if
such service valves are installed.

Summary of Contents for ecoTEC plus VU 6/6-5 OVZ Series

Page 1: ...ting instructions ecoTEC plus VU 6 6 5 OVZ H GB GB IE Operating instructions Publisher manufacturer Vaillant GmbH Berghauser Str 40 D 42859 Remscheid Tel 49 21 91 18 0 Fax 49 21 91 18 2810 info vailla...

Page 2: ...2 Opening and closing the front flap 11 4 3 Switching on the product 11 4 4 Setting the language 11 4 5 Setting the hot water temperature 11 4 6 Setting the heating flow temperature 11 4 7 Switching o...

Page 3: ...al heating installations and for hot water generation Intended use includes the fol lowing observance of the operating instructions included for the product and any other system components compliance...

Page 4: ...rooms that smell of gas If possible open doors and windows fully and ensure adequate ventilation Do not use naked flames e g lighters matches Do not smoke Do not use any electrical switches mains plug...

Page 5: ...not make any changes The product itself to the gas air water and electricity supplies to the entire flue gas install ation to the entire condensate drain system to the expansion relief valve to the d...

Page 6: ...t all rooms are sufficiently heated If you cannot ensure the op eration have a competent person drain the heating in stallation 1 3 11 Risk of injury and material damage due to maintenance and repairs...

Page 7: ...formation on the identification plate The identification plate is mounted on the underside of the product in the factory The identification plate keeps record of the country in which the product is to...

Page 8: ...ties on both manufacturers and installers The purpose is to ensure that customers are provided with the correct equipment for their needs that it is installed commissioned and serviced in accordance w...

Page 9: ...t burner modulation rate Sym bol Meaning Explanation Heating mode active Permanently on Heating mode heat requirement Flashing Burner on in heating mode Maintenance re quired Information on the mainte...

Page 10: ...switch back to the basic display by Pressing to exit the selection levels Not pressing any button for longer than 15 minutes If there is an error message present the basic displays switches to the err...

Page 11: ...st Le gionella Set the hot water temperature to a maximum of 50 C 45 DHW temperature Back 1 Press The set hot water temperature flashes in the display Conditions No controller connected Change the hot...

Page 12: ...and that all rooms are sufficiently heated even when you are away Note To keep the frost protection devices active you should switch your product on and off using the controller if one is provided If...

Page 13: ...in pipe work and tundish If you notice a fault have it rectified by a competent person 7 4 Reading maintenance messages If the symbol is shown in the display the product requires maintenance work The...

Page 14: ...approved at the time by the Health and Safety Executive one year after install ation The cost of this annual service is not included in the guarantee Registering with us Registration is simple Just co...

Page 15: ...ng is dis connected Check the fuse in the building The product switches on automat ically when the power is restored The product is switched off Switch on the product The heating flow temperature is s...

Page 16: ...Operating instructions ecoTEC plus 0020239012_02 Fault Cause Measure Heating does not start The external controller is not set cor rectly Set the external controller cor rectly Controller operating in...

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ...e DE56 1JT Telephone 0330 100 3461 info vaillant co uk www vaillant co uk These instructions or parts thereof are protected by copyright and may be reproduced or distributed only with the manufacturer...

Reviews: