Supplied By www.heating spares.co Tel. 0161 620 6677
44
Instructions for installation and servicing ecoTEC
First Diagnostic level
• Press the “
i
” and “
+
” keys simultaneously.
The display shows “
d.0
”.
• Use the “
+
” or “
–
” keys to scroll through the desired
diagnostic numbers of the first diagnostic level (see
table 8.2).
• Press the “
i
” key.
The display shows the relevant diagnostic information.
• If necessary, use the “
+
” or “
–
” keys to change the
value (display flashes).
• Save the new value by holding down the “
i
” key for
approx. 5 seconds until the display no longer flashes.
Display
Meaning
Display value/adjustable value
d. 0
Heating part load
Adjustable heating part load in kW (factory setting: max. output)
d. 1
Water pump over run time for heating mode
2 - 60 min (factory setting: 5 min)
d. 2
Max. burner anti cycling period at 20 °C Flow tempera-
ture
2 - 60 min (factory setting: 20 min)
d. 3
Hot water flow temperature reading (combination boiler
only)
in °C
d. 4
Current temperature for warm start sensor
(combination boilers only)
Current storage tank sensor (system boilers only)
in °C
d. 5
Flow temperature target value or return target value
when return regulation is set.
in °C, max. the value set in d.71
Limited by the eBUS controller (if an eBUS controller is connected)
d. 6
Hot water temperature target value
in °C, 35 to 65 °C
d. 7
Warm start temperature target value
(ecoTEC plus combination boiler only)
Storage temperature target value (system boiler only)
in °C, 40 to 65 °C
in °C, 15 °C for left stop, then 40 to 70 °C
d. 8
External controls heat demand (Clamp 3-4)
0 = open (no heat request)
1 = closed (heat request)
d. 9
Flow target temperature from external analogue regula-
tor to terminal 7-8-9/eBUS
in °C, minimum from ext. eBUS target value and target value terminal
7
d.10
Status internal heating pump
1 = on, 0 = off
d.11
Status external heating pump
1 to 100 = on, 0 = off
d.12
Cylinder charging pump (via accessory module)
1 to 100 = on, 0 = off
d.13
Hot water circulation pump (via accessory module)
1 to 100 = on, 0 = off
d.22
Hot water demand
1 = on, 0 = off
d.23
Summer/Winter function
1 = Winter, 0 = Summer
d.25
Hot water activation via eBUS Control
1 = yes, 0 = no
d.30
Control signal for both gas valves
1 = on, 0 = off
d.33
Fan speed target value
in rpm/10
d.34
Fan speed actual value
in rpm/10
d.35
Position of diverter valve (combination boilers only)
0 = Heating; 100 = Hot water; 40 = Centre position
d.36
Hot water flow sensor
in l/min
d.40
Flow temperature
Actual value in °C
d.41
Return temperature
Actual value in °C
d.44
Digitised ionisation potential
Display range of 0 to 102, > 80 no flame, < 40 even flame
d.47
Outside temperature
(with weather compensating Vaillant controller only)
Actual value in °C
d.67
Remaining burner anti cycling time
in min
d.76
Appliance variant (device specific number)
00 to 99
d.90
Digital regulator status
1 = identified, 0 = unidentified (eBUS Address <=10)
d.91
DCF status with connected external probe with DCF77
receiver
0 = no reception, 1 = reception, 2 = synchronised, 3 = valid
d.97
Activation of the second diagnostic level
Password: 17
Table 8.2 Diagnostic codes of the first diagnostic level
You can end the diagnostic mode as follows:
• Press the “
i
” and “
+
” keys simultaneously.
or
• Do not press any key for approx. 4 minutes.
The current heating flow temperature appears in the dis-
play again.
8 Troubleshooting
Summary of Contents for ecoTEC plus 612
Page 54: ...Supplied By www heating spares co Tel 0161 620 6677...
Page 55: ...Supplied By www heating spares co Tel 0161 620 6677...
Page 56: ...Supplied By www heating spares co Tel 0161 620 6677 839592_05 GB 08 2006...
Page 122: ...Supplied By www heating spares co Tel 0161 620 6677...
Page 124: ...Supplied By www heating spares co Tel 0161 620 6677 0020010870 01 GB 03 2006 2...
Page 142: ...Supplied By www heating spares co Tel 0161 620 6677 0020010870 01 GB 03 2006 20...
Page 162: ...Supplied By www heating spares co Tel 0161 620 6677 Notes 0020010870 01 GB 03 2006 40...
Page 163: ...Supplied By www heating spares co Tel 0161 620 6677...
Page 179: ...Supplied By www heating spares co Tel 0161 620 6677 15 Instructions for use ecoTEC...
Page 180: ...Supplied By www heating spares co Tel 0161 620 6677 16 Instructions for use ecoTEC...
Page 181: ...Supplied By www heating spares co Tel 0161 620 6677 20 C 20 C 15 C 5 C bar bar VRT VRC i F P...
Page 182: ...Supplied By www heating spares co Tel 0161 620 6677...
Page 183: ...Supplied By www heating spares co Tel 0161 620 6677 19 Instructions for use ecoTEC...
Page 184: ...Supplied By www heating spares co Tel 0161 620 6677 838402_04 GB 08 2006...