Supplied By www.heating spares.co Tel. 0161 620 6677
41
Instructions for installation and servicing ecoTEC
• Tighten the four nuts (
4
) on the alternate left and
right sides until the burner door fits closely and uni-
formly to the stop surfaces.
• Reconnect the HT lead (
5
) and earth lead (
6
) to the
spark electrode.
• Insert the cables (
8
) on the fan motor and the cable
(
7
) on the gas fitting.
2
3
1
Fig. 7.7 Refitting the gas supply
• Reconnect the gas supply (
3
) to the gas valve, ensur-
ing that a new sealing washer is used and correctly
located. Use the spanner flat at the flexible gas line to
hold the gas fittings.
11
Fig. 7.8 Testing the gas supply for soundness
• Turn on the gas supply and test for soundness. Check
especially the screwed connections (
3
) and (
11
).
• Refit the air inlet pipe, ensuring that the blue seal in
the air intake pipe is correctly located.
7.3
Cleaning the condensate siphon
1
Fig. 7.9 Cleaning the condensate siphon
Danger!
Note that if the boiler is run with an empty
condensate trap there is a danger that fumes
might escape into the room and cause poison-
ing. For this reason, it is important to ensure
that the trap is topped up each time the unit is
cleaned.
• Remove the lower part (
1
) of the condensate siphon by
turning the bayonet catch in anticlockwise direction.
• Clean the siphon part section by rinsing it out with
water.
• Fill the lower part with water until about 10 mm below
the upper edge.
• Fasten the lower part again on the condensate siphon.
Inspection and maintenance 7
Summary of Contents for ecoTEC plus 612
Page 54: ...Supplied By www heating spares co Tel 0161 620 6677...
Page 55: ...Supplied By www heating spares co Tel 0161 620 6677...
Page 56: ...Supplied By www heating spares co Tel 0161 620 6677 839592_05 GB 08 2006...
Page 122: ...Supplied By www heating spares co Tel 0161 620 6677...
Page 124: ...Supplied By www heating spares co Tel 0161 620 6677 0020010870 01 GB 03 2006 2...
Page 142: ...Supplied By www heating spares co Tel 0161 620 6677 0020010870 01 GB 03 2006 20...
Page 162: ...Supplied By www heating spares co Tel 0161 620 6677 Notes 0020010870 01 GB 03 2006 40...
Page 163: ...Supplied By www heating spares co Tel 0161 620 6677...
Page 179: ...Supplied By www heating spares co Tel 0161 620 6677 15 Instructions for use ecoTEC...
Page 180: ...Supplied By www heating spares co Tel 0161 620 6677 16 Instructions for use ecoTEC...
Page 181: ...Supplied By www heating spares co Tel 0161 620 6677 20 C 20 C 15 C 5 C bar bar VRT VRC i F P...
Page 182: ...Supplied By www heating spares co Tel 0161 620 6677...
Page 183: ...Supplied By www heating spares co Tel 0161 620 6677 19 Instructions for use ecoTEC...
Page 184: ...Supplied By www heating spares co Tel 0161 620 6677 838402_04 GB 08 2006...